Your browser doesn't support javascript.
loading
Breast Imaging Utilizing Dedicated Gamma Camera and (99m)Tc-MIBI: Experience at the Tel Aviv Medical Center and Review of the Literature Breast Imaging.
Even-Sapir, Einat; Golan, Orit; Menes, Tehillah; Weinstein, Yuliana; Lerman, Hedva.
Afiliação
  • Even-Sapir E; Department of Nuclear Medicine, Tel Aviv Sourasky Medical Center, Tel Aviv University, Tel Aviv, Israel; Sackler School of Medicine, Tel Aviv University, Tel Aviv, Israel. Electronic address: evensap@tlvmc.gov.il.
  • Golan O; Department of Radiology, Tel Aviv Sourasky Medical Center, Tel Aviv University, Tel Aviv, Israel; Breast Imaging Unit, Tel Aviv Sourasky Medical Center, Tel Aviv University, Tel Aviv, Israel.
  • Menes T; Department of Surgery, Tel Aviv Sourasky Medical Center, Tel Aviv University, Tel Aviv, Israel; Breast surgery unit, Tel Aviv Sourasky Medical Center, Tel Aviv University, Tel Aviv, Israel; Sackler School of Medicine, Tel Aviv University, Tel Aviv, Israel.
  • Weinstein Y; Department of Radiology, Tel Aviv Sourasky Medical Center, Tel Aviv University, Tel Aviv, Israel; Breast Imaging Unit, Tel Aviv Sourasky Medical Center, Tel Aviv University, Tel Aviv, Israel.
  • Lerman H; Department of Nuclear Medicine, Tel Aviv Sourasky Medical Center, Tel Aviv University, Tel Aviv, Israel.
Semin Nucl Med ; 46(4): 286-93, 2016 07.
Article em En | MEDLINE | ID: mdl-27237439
ABSTRACT
The scope of the current article is the clinical role of gamma cameras dedicated for breast imaging and (99m)Tc-MIBI tumor-seeking tracer, as both a screening modality among a healthy population and as a diagnostic modality in patients with breast cancer. Such cameras are now commercially available. The technology utilizing a camera composed of a NaI (Tl) detector is termed breast-specific gamma imaging. The technology of dual-headed camera composed of semiconductor cadmium zinc telluride detectors that directly converts gamma-ray energy into electronic signals is termed molecular breast imaging. Molecular breast imaging system has been installed at the Department of Nuclear medicine at the Tel Aviv Sourasky Medical Center, Tel Aviv in 2009. The article reviews the literature well as our own experience.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Mama / Cintilografia / Tecnécio Tc 99m Sestamibi / Centros Médicos Acadêmicos Limite: Humans País/Região como assunto: Asia Idioma: En Revista: Semin Nucl Med Ano de publicação: 2016 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Mama / Cintilografia / Tecnécio Tc 99m Sestamibi / Centros Médicos Acadêmicos Limite: Humans País/Região como assunto: Asia Idioma: En Revista: Semin Nucl Med Ano de publicação: 2016 Tipo de documento: Article
...