Your browser doesn't support javascript.
loading
Quantitative determination of gracillin by HPLC-MS/MS after oral administration and its application to a pharmacokinetic study.
Zhang, Xinxin; Xue, Xuanji; Zhao, Jing; Guo, Zengjun; Ito, Yoichiro; Sun, Wenji.
Afiliação
  • Zhang X; College of Pharmacy, Xi'an Jiaotong Univeristy, Xi'an 710061, China.
  • Xue X; College of Pharmacy, Xi'an Jiaotong Univeristy, Xi'an 710061, China.
  • Zhao J; College of Pharmacy, Xi'an Jiaotong Univeristy, Xi'an 710061, China.
  • Guo Z; College of Pharmacy, Xi'an Jiaotong Univeristy, Xi'an 710061, China. Electronic address: guozj@mail.xjtu.edu.cn.
  • Ito Y; Laboratory of Bioseparation Technology, Biochemistry and Biophysics Center, National Heart, Lung, and Blood Institute, National Institutes of Health, Bethesda, MD, USA.
  • Sun W; Biomedicine Key Laboratory of Shaanxi Province, Northwest University, Xi'an 710069, China. Electronic address: cxbml360@126.com.
Steroids ; 113: 78-86, 2016 09.
Article em En | MEDLINE | ID: mdl-27394958
ABSTRACT
A sensitive and credible high performance liquid chromatography hyphenated to mass spectrometry (HPLC-MS/MS) was established to quantify the concentration of gracillin in rat plasma. The plasma samples were subjected to a direct protein precipitation process with acetonitrile as a precipitant in a single-step. Ginsenoside Rb1 was selected as an internal standard (IS). The chromatographic separation of analyte and IS were carried out on an Inersil ODS-3 C18 column (250×4.6mm, 5µm) with a binary solvent system containing acetonitrile and 0.1% formic acid in water at a flow rate of 1mLmin(-1) under a gradient elution mode. Mass spectrometric detection was performed on a triple quadrupole tandem mass spectrometer by the multiple reaction monitoring (MRM) mode to examine the precursor-to-daughter ion transitions of 1110.3→948.2 for IS and 886.1→739.9 for gracillin, respectively, in a positive electrospray ionization mode. The calibration curve showed a promising linearity over a concentration range of 0.065-800ngmL(-1) with a better regression coefficient of r(2)=0.9960. The intra- and inter-day precisions (as relative standard deviation) of the assay at three quality control levels were all less than 3.48%, while the intra- and inter-day accuracies (as relative error) ranged from -8.43% to 9.74%, whose data were within the acceptable limits. The mean extraction recoveries of analyte from rat plasma were all more than 74.11%, and no notable matrix effect was observed. Stability experiments revealed that gracillin remained stable throughout the analytical procedure under various stored conditions. The above validated method was successfully used to investigate the pharmacokinetic behaviors of gracillin orally administrated to rats at three proportion doses. The pharmacokinetic analysis would pave the way for understanding the pharmacological actions and provide a meaningful foundation for further development and application in preclinical and clinical use of gracillin in the near future.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Espirostanos / Cromatografia Líquida de Alta Pressão / Espectrometria de Massas em Tandem Limite: Animals Idioma: En Revista: Steroids Ano de publicação: 2016 Tipo de documento: Article País de afiliação: China

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Espirostanos / Cromatografia Líquida de Alta Pressão / Espectrometria de Massas em Tandem Limite: Animals Idioma: En Revista: Steroids Ano de publicação: 2016 Tipo de documento: Article País de afiliação: China
...