Your browser doesn't support javascript.
loading
X-ray diffraction and NMR data for the study of the location of idebenone and idebenol in model membranes.
Gómez-Murcia, Victoria; Torrecillas, Alejandro; deGodos, Ana M; Corbalán-García, Senena; Gómez-Fernández, Juan C.
Afiliação
  • Gómez-Murcia V; Departamento de Bioquímica y Biología Molecular A, Universidad de Murcia, IMIB-Arrixaca, Campus of International Excellence "Campus Mare Nostrum", Murcia, Spain.
  • Torrecillas A; Departamento de Bioquímica y Biología Molecular A, Universidad de Murcia, IMIB-Arrixaca, Campus of International Excellence "Campus Mare Nostrum", Murcia, Spain.
  • deGodos AM; Departamento de Bioquímica y Biología Molecular A, Universidad de Murcia, IMIB-Arrixaca, Campus of International Excellence "Campus Mare Nostrum", Murcia, Spain.
  • Corbalán-García S; Departamento de Bioquímica y Biología Molecular A, Universidad de Murcia, IMIB-Arrixaca, Campus of International Excellence "Campus Mare Nostrum", Murcia, Spain.
  • Gómez-Fernández JC; Departamento de Bioquímica y Biología Molecular A, Universidad de Murcia, IMIB-Arrixaca, Campus of International Excellence "Campus Mare Nostrum", Murcia, Spain.
Data Brief ; 7: 981-9, 2016 Jun.
Article em En | MEDLINE | ID: mdl-27408910
ABSTRACT
Here we present some of our data about the interaction of idebenone and idebenol with dipalmitoyl-phosphatidylcholine (DPPC). In particular, we include data of small angle X-ray diffraction (SAXD) and wide angle X-ray diffraction experiments, obtention of electronic profiles of the membranes, (2)H-NMR and (31)P-NMR, as part of the research article "Both idebenone and idebenol are localized near the lipid-water interface of the membrane and increase its fluidity" (Gomez-Murcia et al., 2016) [1]. These data were obtained from model membranes that included different proportions of idebenone and idebenol, at temperatures both above and below of the gel to fluid phase. The X-ray experiments were carried out by using a modified Kratky compact camera (MBraun-Graz-Optical Systems, Graz Austria), incorporating two coupled linear position sensitive detectors. The NMR data were collected from a a Bruker Avance 600 instrument.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Data Brief Ano de publicação: 2016 Tipo de documento: Article País de afiliação: Espanha

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Data Brief Ano de publicação: 2016 Tipo de documento: Article País de afiliação: Espanha
...