Your browser doesn't support javascript.
loading
Length-free near infrared measurement of newborn malnutrition.
Mustafa, Fatin Hamimi; Bek, Emily J; Huvanandana, Jacqueline; Jones, Peter W; Carberry, Angela E; Jeffery, Heather E; Jin, Craig T; McEwan, Alistair L.
Afiliação
  • Mustafa FH; School of Electrical and Information Engineering, Faculty of Engineering and Information Technologies, University of Sydney, New South Wales, Australia.
  • Bek EJ; School of Electrical and Information Engineering, Faculty of Engineering and Information Technologies, University of Sydney, New South Wales, Australia.
  • Huvanandana J; School of Electrical and Information Engineering, Faculty of Engineering and Information Technologies, University of Sydney, New South Wales, Australia.
  • Jones PW; School of Electrical and Information Engineering, Faculty of Engineering and Information Technologies, University of Sydney, New South Wales, Australia.
  • Carberry AE; School of Electrical and Information Engineering, Faculty of Engineering and Information Technologies, University of Sydney, New South Wales, Australia.
  • Jeffery HE; School of Electrical and Information Engineering, Faculty of Engineering and Information Technologies, University of Sydney, New South Wales, Australia.
  • Jin CT; Sydney School of Public Health, University of Sydney, New South Wales, Australia.
  • McEwan AL; Former Senior Staff Specialist in Neonatology, Royal Prince Alfred Hospital, Sydney, Australia.
Sci Rep ; 6: 36052, 2016 11 08.
Article em En | MEDLINE | ID: mdl-27824061
ABSTRACT
Under-nutrition in neonates can cause immediate mortality, impaired cognitive development and early onset adult disease. Body fat percentage measured using air-displacement-plethysmography has been found to better indicate under-nutrition than conventional birth weight percentiles. However, air-displacement-plethysmography equipment is expensive and non-portable, so is not suited for use in developing communities where the burden is often the greatest. We proposed a new body fat measurement technique using a length-free model with near-infrared spectroscopy measurements on a single site of the body - the thigh. To remove the need for length measurement, we developed a model with five discrete wavelengths and a sex parameter. The model was developed using air-displacement-plethysmography measurements in 52 neonates within 48 hours of birth. We identified instrumentation required in a low-cost LED-based screening device and incorporated a receptor device that can increase the amount of light collected. This near-infrared method may be suitable as a low cost screening tool for detecting body fat levels and monitoring nutritional interventions for malnutrition in neonates and young children in resource-constrained communities.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Contexto em Saúde: 2_ODS3 / 6_ODS3_enfermedades_notrasmisibles / 7_ODS3_muertes_prevenibles_nacidos_ninos Problema de saúde: 2_muertes_prevenibles / 6_malnutrition_nutritional_deficiencies / 7_nutrition Assunto principal: Coxa da Perna / Tecido Adiposo / Espectroscopia de Luz Próxima ao Infravermelho / Desnutrição Tipo de estudo: Prognostic_studies / Screening_studies Aspecto: Determinantes_sociais_saude Limite: Humans / Newborn Idioma: En Revista: Sci Rep Ano de publicação: 2016 Tipo de documento: Article País de afiliação: Austrália

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Contexto em Saúde: 2_ODS3 / 6_ODS3_enfermedades_notrasmisibles / 7_ODS3_muertes_prevenibles_nacidos_ninos Problema de saúde: 2_muertes_prevenibles / 6_malnutrition_nutritional_deficiencies / 7_nutrition Assunto principal: Coxa da Perna / Tecido Adiposo / Espectroscopia de Luz Próxima ao Infravermelho / Desnutrição Tipo de estudo: Prognostic_studies / Screening_studies Aspecto: Determinantes_sociais_saude Limite: Humans / Newborn Idioma: En Revista: Sci Rep Ano de publicação: 2016 Tipo de documento: Article País de afiliação: Austrália
...