Your browser doesn't support javascript.
loading
Evaluating the Application of Tissue-Specific Dose Kernels Instead of Water Dose Kernels in Internal Dosimetry: A Monte Carlo Study.
Khazaee Moghadam, Maryam; Kamali Asl, Alireza; Geramifar, Parham; Zaidi, Habib.
Afiliação
  • Khazaee Moghadam M; 1 Department of Radiation Medicine Engineering, Shahid Beheshti University , Tehran, Iran .
  • Kamali Asl A; 1 Department of Radiation Medicine Engineering, Shahid Beheshti University , Tehran, Iran .
  • Geramifar P; 2 Research Center for Nuclear Medicine, Shariati Hospital, Tehran University of Medical Sciences , Tehran, Iran .
  • Zaidi H; 3 Division of Nuclear Medicine and Molecular Imaging, Geneva University Hospital , Geneva, Switzerland .
Cancer Biother Radiopharm ; 31(10): 367-379, 2016 Dec.
Article em En | MEDLINE | ID: mdl-27996311
PURPOSE: The aim of this work is to evaluate the application of tissue-specific dose kernels instead of water dose kernels to improve the accuracy of patient-specific dosimetry by taking tissue heterogeneities into consideration. MATERIALS AND METHODS: Tissue-specific dose point kernels (DPKs) and dose voxel kernels (DVKs) for yttrium-90 (90Y), lutetium-177 (177Lu), and phosphorus-32 (32P) are calculated using the Monte Carlo (MC) simulation code GATE (version 7). The calculated DPKs for bone, lung, adipose, breast, heart, intestine, kidney, liver, and spleen are compared with those of water. The dose distribution in normal and tumorous tissues in lung, liver, and bone of a Zubal phantom is calculated using tissue-specific DVKs instead of those of water in conventional methods. For a tumor defined in a heterogeneous region in the Zubal phantom, the absorbed dose is calculated using a proposed algorithm, taking tissue heterogeneity into account. The algorithm is validated against full MC simulations. RESULTS: The simulation results indicate that the highest differences between water and other tissue DPKs occur in bone for 90Y (12.2% ± 0.6%), 32P (18.8% ± 1.3%), and 177Lu (16.9% ± 1.3%). The second highest discrepancy corresponds to the lung for 90Y (6.3% ± 0.2%), 32P (8.9% ± 0.4%), and 177Lu (7.7% ± 0.3%). For 90Y, the mean absorbed dose in tumorous and normal tissues is calculated using tissue-specific DVKs in lung, liver, and bone. The results are compared with doses calculated considering the Zubal phantom water equivalent and the relative differences are 4.50%, 0.73%, and 12.23%, respectively. For the tumor in the heterogeneous region of the Zubal phantom that includes lung, liver, and bone, the relative difference between mean calculated dose in tumorous and normal tissues based on the proposed algorithm and the values obtained from full MC dosimetry is 5.18%. CONCLUSIONS: A novel technique is proposed considering tissue-specific dose kernels in the dose calculation algorithm. This algorithm potentially enables patient-specific dosimetry and improves estimation of the average absorbed dose of 90Y in a tumor located in lung, bone, and soft tissue interface by 6.98% compared with the conventional methods.
Assuntos
Palavras-chave
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Radioisótopos / Radiometria / Água Tipo de estudo: Health_economic_evaluation Limite: Humans Idioma: En Revista: Cancer Biother Radiopharm Assunto da revista: FARMACIA / FARMACOLOGIA / NEOPLASIAS / TERAPEUTICA Ano de publicação: 2016 Tipo de documento: Article País de afiliação: Irã
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Radioisótopos / Radiometria / Água Tipo de estudo: Health_economic_evaluation Limite: Humans Idioma: En Revista: Cancer Biother Radiopharm Assunto da revista: FARMACIA / FARMACOLOGIA / NEOPLASIAS / TERAPEUTICA Ano de publicação: 2016 Tipo de documento: Article País de afiliação: Irã
...