Your browser doesn't support javascript.
loading
Use of a postoperative pad test to identify continence status in women after obstetric vesicovaginal fistula repair: a prospective cohort study.
Kopp, D M; Bengtson, A M; Tang, J H; Chipungu, E; Moyo, M; Wilkinson, J.
Afiliação
  • Kopp DM; UNC Project-Malawi, Lilongwe, Malawi.
  • Bengtson AM; UNC Department of Obstetrics & Gynecology, Chapel Hill, NC, USA.
  • Tang JH; UNC Department of Epidemiology, Chapel Hill, NC, USA.
  • Chipungu E; UNC Project-Malawi, Lilongwe, Malawi.
  • Moyo M; UNC Department of Obstetrics & Gynecology, Chapel Hill, NC, USA.
  • Wilkinson J; Fistula Care Centre, Lilongwe, Malawi.
BJOG ; 124(6): 966-972, 2017 May.
Article em En | MEDLINE | ID: mdl-28128507
ABSTRACT

OBJECTIVE:

Determine whether a 1-hour pad test at discharge can identify continence status within 120 days of obstetric vesicovaginal fistula (VVF) repair.

DESIGN:

Prospective cohort study.

SETTING:

Fistula Care Centre in Lilongwe, Malawi. POPULATION Women with VVF who underwent repair between January 2012 and December 2014.

METHODS:

Data on demographics, obstetric history, physical exam findings, operative management, postoperative findings, and follow up evaluations were collected on women with VVF repair. MAIN OUTCOME

MEASURES:

Sensitivity, specificity, positive and negative predictive values (PPV and NPV), and a receiver operating curve (ROC) were calculated to assess the utility of using a discharge pad test at three thresholds to identify women likely to be continent at follow up.

RESULTS:

After VVF repair, 346 women had a 1-hour pad test performed at the time of hospital discharge and completed follow up within 120 days of repair. Of these, 79.8% (n = 276) were completely continent, whereas 20.2% (n = 70) had some degree of incontinence. The sensitivity and specificity of a negative 1-hour pad test at predicting continence is 68.1% and 82.9%, respectively. With this prevalence, a negative pad test at a 1.5-g threshold demonstrates a high predictive value (PPV = 94.0%, 95% CI 90.0-96.9) in detecting women with continence after repair.

CONCLUSIONS:

At the 1.5-g threshold, a negative pad test at discharge identifies 94% of women who will remain continent after VVF repair. Adding the pad test to fistula care can identify women who are likely to remain continent and may not need further therapies in settings where resources are limited and follow up after repair is difficult. TWEETABLE ABSTRACT A negative pad test after repair is associated with continued continence at follow up.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Complicações Pós-Operatórias / Complicações na Gravidez / Incontinência Urinária / Fístula Vesicovaginal / Absorventes Higiênicos Tipo de estudo: Diagnostic_studies / Etiology_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Adult / Female / Humans / Pregnancy País/Região como assunto: Africa Idioma: En Revista: BJOG Assunto da revista: GINECOLOGIA / OBSTETRICIA Ano de publicação: 2017 Tipo de documento: Article País de afiliação: Malauí

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Complicações Pós-Operatórias / Complicações na Gravidez / Incontinência Urinária / Fístula Vesicovaginal / Absorventes Higiênicos Tipo de estudo: Diagnostic_studies / Etiology_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Adult / Female / Humans / Pregnancy País/Região como assunto: Africa Idioma: En Revista: BJOG Assunto da revista: GINECOLOGIA / OBSTETRICIA Ano de publicação: 2017 Tipo de documento: Article País de afiliação: Malauí
...