Your browser doesn't support javascript.
loading
Simultaneous Online Monitoring of Multiple Reactions Using a Miniature Mass Spectrometer.
Pulliam, Christopher J; Bain, Ryan M; Osswald, Heather L; Snyder, Dalton T; Fedick, Patrick W; Ayrton, Stephen T; Flick, Tawnya G; Cooks, R Graham.
Afiliação
  • Pulliam CJ; Department of Chemistry, Purdue University , 560 Oval Drive, West Lafayette, Indiana 47907, United States.
  • Bain RM; Department of Chemistry, Purdue University , 560 Oval Drive, West Lafayette, Indiana 47907, United States.
  • Osswald HL; Department of Chemistry, Purdue University , 560 Oval Drive, West Lafayette, Indiana 47907, United States.
  • Snyder DT; Department of Chemistry, Purdue University , 560 Oval Drive, West Lafayette, Indiana 47907, United States.
  • Fedick PW; Department of Chemistry, Purdue University , 560 Oval Drive, West Lafayette, Indiana 47907, United States.
  • Ayrton ST; Department of Chemistry, Purdue University , 560 Oval Drive, West Lafayette, Indiana 47907, United States.
  • Flick TG; Department of Attribute Sciences, Amgen Inc. , 1 Amgen Center Drive, Thousand Oaks, California 91320, United States.
  • Cooks RG; Department of Chemistry, Purdue University , 560 Oval Drive, West Lafayette, Indiana 47907, United States.
Anal Chem ; 89(13): 6969-6975, 2017 07 05.
Article em En | MEDLINE | ID: mdl-28520396
ABSTRACT
Advances in chemical sampling using miniature mass spectrometer technology are used to monitor slow reactions at a frequency of ca. 180 h-1 (on the Mini 12) with no sample carryover and with inline derivatization in the case of poorly ionizing compounds. Moreover, we demonstrate high reproducibility with a relative error of less than 10% for major components. Monitoring is enabled using a continuous-flow nanoelectrospray (CF-nESI) probe contained in a custom-built 3D-printed rotary holder. The holder position is automatically set using a stepper motor controlled by a microcontroller. Reaction progress of up to six reactions, including hydrazone formation and Katritzky transamination, can be monitored simultaneously without carryover for several hours.

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Anal Chem Ano de publicação: 2017 Tipo de documento: Article País de afiliação: Estados Unidos