Your browser doesn't support javascript.
loading
Broadband W-band Rapid Frequency Sweep Considerations for Fourier Transform EPR.
Strangeway, Robert A; Hyde, James S; Camenisch, Theodore G; Sidabras, Jason W; Mett, Richard R; Anderson, James R; Ratke, Joseph J; Subczynski, Witold K.
Afiliação
  • Strangeway RA; National Biomedical EPR Center, Department of Biophysics, Medical College of Wisconsin, 8701 Watertown Plank Road, Milwaukee, WI, 53226, USA.
  • Hyde JS; Department of Electrical Engineering and Computer Science, Milwaukee School of Engineering, 1025 North Broadway, Milwaukee, WI, 53202, USA.
  • Camenisch TG; National Biomedical EPR Center, Department of Biophysics, Medical College of Wisconsin, 8701 Watertown Plank Road, Milwaukee, WI, 53226, USA. jshyde@mcw.edu.
  • Sidabras JW; National Biomedical EPR Center, Department of Biophysics, Medical College of Wisconsin, 8701 Watertown Plank Road, Milwaukee, WI, 53226, USA.
  • Mett RR; National Biomedical EPR Center, Department of Biophysics, Medical College of Wisconsin, 8701 Watertown Plank Road, Milwaukee, WI, 53226, USA.
  • Anderson JR; National Biomedical EPR Center, Department of Biophysics, Medical College of Wisconsin, 8701 Watertown Plank Road, Milwaukee, WI, 53226, USA.
  • Ratke JJ; Department of Physics and Chemistry, Milwaukee School of Engineering, 1025 North Broadway, Milwaukee, WI, 53202, USA.
  • Subczynski WK; National Biomedical EPR Center, Department of Biophysics, Medical College of Wisconsin, 8701 Watertown Plank Road, Milwaukee, WI, 53226, USA.
Cell Biochem Biophys ; 75(3-4): 259-273, 2017 Dec.
Article em En | MEDLINE | ID: mdl-28555359
A multi-arm W-band (94 GHz) electron paramagnetic resonance spectrometer that incorporates a loop-gap resonator with high bandwidth is described. A goal of the instrumental development is detection of free induction decay following rapid sweep of the microwave frequency across the spectrum of a nitroxide radical at physiological temperature, which is expected to lead to a capability for Fourier transform electron paramagnetic resonance. Progress toward this goal is a theme of the paper. Because of the low Q-value of the loop-gap resonator, it was found necessary to develop a new type of automatic frequency control, which is described in an appendix. Path-length equalization, which is accomplished at the intermediate frequency of 59 GHz, is analyzed. A directional coupler is favored for separation of incident and reflected power between the bridge and the loop-gap resonator. Microwave leakage of this coupler is analyzed. An oversize waveguide with hyperbolic-cosine tapers couples the bridge to the loop-gap resonator, which results in reduced microwave power and signal loss. Benchmark sensitivity data are provided. The most extensive application of the instrument to date has been the measurement of T1 values using pulse saturation recovery. An overview of that work is provided.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Espectroscopia de Ressonância de Spin Eletrônica Idioma: En Revista: Cell Biochem Biophys Assunto da revista: BIOFISICA / BIOQUIMICA Ano de publicação: 2017 Tipo de documento: Article País de afiliação: Estados Unidos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Espectroscopia de Ressonância de Spin Eletrônica Idioma: En Revista: Cell Biochem Biophys Assunto da revista: BIOFISICA / BIOQUIMICA Ano de publicação: 2017 Tipo de documento: Article País de afiliação: Estados Unidos
...