Your browser doesn't support javascript.
loading
Strip meniscometry in dogs, cats, and rabbits.
Rajaei, Seyed Mehdi; Ansari Mood, Maneli; Asadi, Faezeh; Rajabian, Mohammad Reza; Aghajanpour, Leila.
Afiliação
  • Rajaei SM; Department of Clinical Sciences, College of Veterinary Medicine, Karaj Branch, Islamic Azad University, Alborz, Iran.
  • Ansari Mood M; Department of Clinical Sciences, College of Veterinary Medicine, Science and Research Branch, Islamic Azad University, Tehran, Iran.
  • Asadi F; Faculty of Veterinary Medicine, University of Semnan, Semnan, Iran.
  • Rajabian MR; Faculty of veterinary medicine, University of Tehran, Tehran, Iran.
  • Aghajanpour L; Stem Cell Preparation Unit, Farabi Eye Hospital, Tehran University of Medical Sciences, Tehran, Iran.
Vet Ophthalmol ; 21(2): 210-213, 2018 Mar.
Article em En | MEDLINE | ID: mdl-28653355
ABSTRACT

OBJECTIVE:

The purpose of this study was to establish the normal values of strip meniscometry (SM) as a lacrimal function test and to compare the results with Schirmer tear test I (STT I) in dogs, cats, and rabbits. ANIMALS STUDIED Sixty healthy adult dogs from twelve different breeds (120 eyes), twenty adult healthy domestic shorthair cats (40 eyes) and eighteen adult healthy New Zealand white rabbits (36 eyes) were used in this study. PROCEDURES Lacrimal function was tested by SM tube in all animals. After 24 h at the same time of day, tear production was measured using STT I.

RESULTS:

Mean SM and STT I values for all of the dogs, cats, and rabbits were 9.66 ± 2.15 mm/5 s and 15.10 ± 3.06 mm/min; 10.50 ± 0.7 mm/5 s and 11.00 ± 1.41 mm/min; 4.72 ± 1.20 mm/5 s and 4.22 ± 2.47 mm/min, respectively. There was a correlation (r = 0.281; P = 0.018) between SM and STT I values in dogs, but no correlation was observed in cats and rabbits (P = 0.61, P = 0.06). No correlation was found between age of animals and obtained SM values in each species (P > 0.29). Sex had no effect on SM values in each species (P > 0.08).

CONCLUSIONS:

The result of this study provided the normal clinical values of strip meniscometry as lacrimal function test in three species.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Coelhos / Gatos / Técnicas de Diagnóstico Oftalmológico / Cães / Aparelho Lacrimal Tipo de estudo: Evaluation_studies Limite: Animals Idioma: En Revista: Vet Ophthalmol Assunto da revista: MEDICINA VETERINARIA / OFTALMOLOGIA Ano de publicação: 2018 Tipo de documento: Article País de afiliação: Irã

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Coelhos / Gatos / Técnicas de Diagnóstico Oftalmológico / Cães / Aparelho Lacrimal Tipo de estudo: Evaluation_studies Limite: Animals Idioma: En Revista: Vet Ophthalmol Assunto da revista: MEDICINA VETERINARIA / OFTALMOLOGIA Ano de publicação: 2018 Tipo de documento: Article País de afiliação: Irã
...