Your browser doesn't support javascript.
loading
Diagnostic accuracy of 18F-FDG PET or PET/CT for the characterization of adrenal masses: a systematic review and meta-analysis.
Kim, Seong-Jang; Lee, Sang-Woo; Pak, Kyoungjune; Kim, In-Ju; Kim, Keunyoung.
Afiliação
  • Kim SJ; 1 Department of Nuclear Medicine, Pusan National University Yangsan Hospital , Yangsan , South Korea.
  • Lee SW; 2 BioMedical Research Institute for Convergence of Biomedical Science and Technology, Pusan National University Yangsan Hospital , Yangsan , South Korea.
  • Pak K; 3 Department of Nuclear Medicine, Kyungpook National University Medical Center and School of Medicine , Daegu , South Korea.
  • Kim IJ; 4 Department of Nuclear Medicine and Biomedical Research Institute, Pusan National University Hospital , Busan , South Korea.
  • Kim K; 4 Department of Nuclear Medicine and Biomedical Research Institute, Pusan National University Hospital , Busan , South Korea.
Br J Radiol ; 91(1086): 20170520, 2018 Jun.
Article em En | MEDLINE | ID: mdl-29327944
ABSTRACT

OBJECTIVE:

We aimed to explore the role of the diagnostic accuracy of 18F fluodeoxyglucose PET (18F-FDG PET) or PET/CT for characterization of adrenal lesions through a systematic review and meta-analysis.

METHODS:

The MEDLINE, EMBASE, and Cochrane Library database, from the earliest available date of indexing through 30 April 2017, were searched for studies evaluating the diagnostic performance of 18F-FDG PET or PET/CT for characterization of adrenal lesions. We determined the sensitivities and specificities across studies, calculated positive and negative likelihood ratios (LR + and LR-), and constructed summary receiver operating characteristic curves.

RESULTS:

Across 29 studies (2421 patients), the pooled sensitivity for 18F-FDG PET or PET/CT was 0.91 [95% CI (0.88-0.94)] with heterogeneity (χ2 = 141.8, p = 0.00) and a pooled specificity of 0.91 [95% CI (0.87-0.93)] with heterogeneity (χ2 = 113.7, p = 0.00). Likelihood ratio (LR) syntheses gave an overall positive likelihood ratio (LR+) of 9.9 [95% CI (7.1-13.7)] and negative likelihood ratio (LR-) of 0.09 [95% CI (0.07-0.13)]. The pooled diagnostic odds ratio was 105 [95% CI (63-176)]. In metaregression analysis, study design, publication year, study location (western vs others), interpretation criteria of PET or PET/CT images, quantification of PET or PET/CT [SUVmax (maximum standardized uptake value) vs SUV (standardized uptake value) ratio], patient group, and analysis method (patient-based vs lesion-based) were the sources of the study heterogeneity. However, in multivariate metaregression, no definite variable was the source of the study heterogeneity.

CONCLUSION:

18F-FDG PET or PET/CT demonstrated good sensitivity and specificity for the characterization of adrenal masses. At present, the literature regarding the use of 18F-FDG PET or PET/CT for the characterization of adrenal masses remains still limited; thus, further large multicenter studies would be necessary to substantiate the diagnostic accuracy of 18F-FDG PET or PET/CT characterization of adrenal masses. Advances in knowledge 18F- FDG PET or PET/CT showed good sensitivity and specificity for the characterization of adrenal masses and could provide additional information for that purpose.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Adenoma / Neoplasias das Glândulas Suprarrenais / Compostos Radiofarmacêuticos / Fluordesoxiglucose F18 / Tomografia por Emissão de Pósitrons / Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada Tipo de estudo: Clinical_trials / Diagnostic_studies / Systematic_reviews Limite: Humans Idioma: En Revista: Br J Radiol Ano de publicação: 2018 Tipo de documento: Article País de afiliação: Coréia do Sul

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Adenoma / Neoplasias das Glândulas Suprarrenais / Compostos Radiofarmacêuticos / Fluordesoxiglucose F18 / Tomografia por Emissão de Pósitrons / Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada Tipo de estudo: Clinical_trials / Diagnostic_studies / Systematic_reviews Limite: Humans Idioma: En Revista: Br J Radiol Ano de publicação: 2018 Tipo de documento: Article País de afiliação: Coréia do Sul
...