Your browser doesn't support javascript.
loading
VALIDATION OF MONTE CARLO DOSE CALCULATION FOR PAEDIATRIC CT EXAMINATIONS USING TUBE CURRENT MODULATION BASED ON IN-PHANTOM DOSIMETRY.
Fujii, K; Nomura, K; Muramatsu, Y; Obara, S; Goto, T; Akahane, K; Ota, H; Tsukagoshi, S; Kusumoto, M.
Afiliação
  • Fujii K; Department of Radiological Sciences, Nagoya University Graduate School of Medicine, 1-1-20, Daikominami, Higashi-ku, Nagoya, Japan.
  • Nomura K; Department of Radiological Technology, National Cancer Center Hospital East, 6-5-1 Kashiwanoha, Kashiwa, Japan.
  • Muramatsu Y; Department of Radiation Measurement and Dose Assessment, National Institute of Radiological Sciences, National Institutes for Quantum and Radiological Science and Technology, 4-9-1 Anagawa, Inage-ku, Chiba, Japan.
  • Obara S; Department of Radiological Technology, National Cancer Center Hospital East, 6-5-1 Kashiwanoha, Kashiwa, Japan.
  • Goto T; Department of Radiological Technology, National Cancer Center Hospital East, 6-5-1 Kashiwanoha, Kashiwa, Japan.
  • Akahane K; Department of Radiation Measurement and Dose Assessment, National Institute of Radiological Sciences, National Institutes for Quantum and Radiological Science and Technology, 4-9-1 Anagawa, Inage-ku, Chiba, Japan.
  • Ota H; Canon Medical Systems Corporation, 1385 Shimoishigami, Otawara, Tochigi, Japan.
  • Tsukagoshi S; Department of Radiation Measurement and Dose Assessment, National Institute of Radiological Sciences, National Institutes for Quantum and Radiological Science and Technology, 4-9-1 Anagawa, Inage-ku, Chiba, Japan.
  • Kusumoto M; Department of Radiological Technology, National Cancer Center Hospital East, 6-5-1 Kashiwanoha, Kashiwa, Japan.
Radiat Prot Dosimetry ; 182(4): 508-517, 2018 Dec 01.
Article em En | MEDLINE | ID: mdl-30032259
ABSTRACT
The aim of this study is to estimate tube current modulation (TCM) profiles in paediatric computed tomography (CT) examinations with a TCM scheme (Volume-EC) and evaluate the estimation accuracy of TCM profiles. Another aim is to validate organ doses calculated using Monte Carlo-based CT dosimetry software and estimated TCM profiles by comparing them with those measured using 5-year-old and 10-year-old anthropomorphic phantoms and radio-photoluminescence glass dosemeters. Dose calculations were performed by inputting detailed descriptions of a CT scanner, scan parameters and CT images of the phantoms into the software. Organ doses were evaluated from the calculated dose distribution images. Average relative differences (RDs) between the estimated and actual TCM profiles ranged from -3.6 to 5.6%. RDs between the calculated and measured organ doses ranged from -4.2 to 13.0% and -18.1 to 4.9% for 5-year-old and 10-year-old phantoms, respectively. These results validate dose calculations for paediatric CT scans using TCM.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Contexto em Saúde: 1_ASSA2030 Problema de saúde: 1_financiamento_saude Assunto principal: Doses de Radiação / Radiometria / Tomografia Computadorizada por Raios X Tipo de estudo: Health_economic_evaluation Limite: Child / Child, preschool / Humans Idioma: En Revista: Radiat Prot Dosimetry Ano de publicação: 2018 Tipo de documento: Article País de afiliação: Japão

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Contexto em Saúde: 1_ASSA2030 Problema de saúde: 1_financiamento_saude Assunto principal: Doses de Radiação / Radiometria / Tomografia Computadorizada por Raios X Tipo de estudo: Health_economic_evaluation Limite: Child / Child, preschool / Humans Idioma: En Revista: Radiat Prot Dosimetry Ano de publicação: 2018 Tipo de documento: Article País de afiliação: Japão
...