Your browser doesn't support javascript.
loading
Whole Body Positron Emission Tomography/Computed Tomography (PET/CT) in the Evaluation of Ophthalmic Tumors.
Jiang, Ping; Liao, Shan-Shan; Lan, Xiao-Li; Jiang, Fa-Gang.
Afiliação
  • Jiang P; Department of Ophthalmology, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, 430022, China.
  • Liao SS; Department of Nuclear Medicine and PET Center, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, 430022, China.
  • Lan XL; Department of Nuclear Medicine and PET Center, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, 430022, China.
  • Jiang FG; Department of Ophthalmology, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, 430022, China. fgjiang@hotmail.com.
Curr Med Sci ; 38(2): 310-317, 2018 Apr.
Article em En | MEDLINE | ID: mdl-30074190
ABSTRACT
The clinical value of whole body positron emission tomography/computed tomography (PET/CT) as an imaging tool in diagnosis of ophthalmic tumors was investigated. The retrospective observational case series were performed on the patients with suspected ophthalmic tumors who underwent whole body PET/CT. The golden standard of diagnosis was the final pathological diagnosis or the results of long-term follow-up for patients without surgery/biopsy. PET/CT findings were compared with the golden standard. The sensitivity, specificity, accuracy and positive likelihood ratio of PET/CT in the detection of ophthalmic tumors were calculated. The clinical application of PET/CT in different types of ophthalmic tumors was evaluated. The results showed that 30 patients (18 males and 12 females) with a mean age of 43.0 years (range 4-63 years) were collected. The mean sizes of orbital tumors and intraocular tumors were 26.8 mm×17.8 mm and 11.2 mm×6.1 mm, respectively. The overall sensitivity, specificity, accuracy and positive likelihood ratio of whole body PET/CT in ophthalmic tumors were 76.5%, 71.4%, 75.0% and 2.67, and were 62.5%, 100% and 70.0% in intraocular tumors, and those were 100%, 60.0% and 84.6% in orbital tumors, respectively. PET/CT findings were applied to help make appropriate treatment options in 27 out of 30 patients (90.0%), and 12 (40.0%) patients changed the treatment strategy. False negative results in 4 cases and false positive results in 2 cases were observed in this series. It was suggested that PET/CT was an effective imaging modality in detecting, diagnosing and developing therapeutic schedule for patients with ophthalmic tumors. It was more sensitive and accurate for detecting orbital tumors than for detecting intraocular tumors.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Imagem Corporal Total / Neoplasias Oculares / Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada Tipo de estudo: Diagnostic_studies Limite: Adolescent / Adult / Child / Child, preschool / Female / Humans / Male / Middle aged Idioma: En Revista: Curr Med Sci Ano de publicação: 2018 Tipo de documento: Article País de afiliação: China

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Imagem Corporal Total / Neoplasias Oculares / Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada Tipo de estudo: Diagnostic_studies Limite: Adolescent / Adult / Child / Child, preschool / Female / Humans / Male / Middle aged Idioma: En Revista: Curr Med Sci Ano de publicação: 2018 Tipo de documento: Article País de afiliação: China
...