Your browser doesn't support javascript.
loading
Long-term graft patency after coronary artery bypass grafting: Effects of morphological and pathophysiological factors.
Tinica, Grigore; Chistol, Raluca Ozana; Enache, Mihail; Leon Constantin, Maria Magdalena; Ciocoiu, Manuela; Furnica, Cristina.
Afiliação
  • Chistol RO; Department of Medical Imaging, "Prof. Dr. George I.M. Georgescu" Cardiovascular Diseases Institute, Iasi-Romania. ralucachistol@gmail.com.
Anatol J Cardiol ; 20(5): 275-282, 2018 Nov.
Article em En | MEDLINE | ID: mdl-30391966
OBJECTIVE: The aim of the present study was to identify morphological and pathophysiological factors associated with long-term patency of grafts used in coronary artery bypass grafting (CABG). METHODS: A total of 127 patients who underwent CABG between 2000 and 2006 and presented for computed tomography evaluation of graft patency at 139.78±36.64 months post-CABG were analyzed. Patients received 340 grafts (2.68 grafts/patient), 399 distal anastomoses (3.14 anastomoses/ patient), 220 (55.14%) performed using arterial grafts, and 179 (44.86%) using saphenous vein grafts (SVGs). RESULTS: Graft patency varied according to vessel type and coronary territory. Overall graft patency was 90.16% for the left internal thoracic artery (LITA), 75.55% for the right internal thoracic artery (RITA), 79.25% for the radial artery (RA), and 74.3% for the SVG. The maximum patency rate was obtained with the RA (80.65%) for the right coronary territory, RITA (92.86%) for the anterolateral territory, and SVG (82.54%) for the circumflex territory. The LITA-left anterior descending artery graft occluded in 13 (7.93%) cases, 7 due to competitive flow. The influence of graft length on patency rates after indexing to height was not significant. The target vessel degree of stenosis influenced arterial graft patency rates with an occlusion odds ratio (OR) of 3.02 when anastomosed to target vessels with <90% stenosis. Target vessel caliber also influenced patency rates with occlusion ORs of 2.63 for SVGs and 2.31 for arterial grafts when anastomosed to ≤1.5 mm target vessels. CONCLUSION: Morphological parameters, such as graft type, target territory, target vessel caliber, and degree of stenosis, are important factors conditioning long-term graft patency.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Grau de Desobstrução Vascular / Ponte de Artéria Coronária / Oclusão Coronária Tipo de estudo: Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Aged / Female / Humans / Male Idioma: En Revista: Anatol J Cardiol Ano de publicação: 2018 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Grau de Desobstrução Vascular / Ponte de Artéria Coronária / Oclusão Coronária Tipo de estudo: Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Aged / Female / Humans / Male Idioma: En Revista: Anatol J Cardiol Ano de publicação: 2018 Tipo de documento: Article
...