Your browser doesn't support javascript.
loading
Fast isotropic volumetric magnetic resonance imaging of the ankle: Acceleration of the three-dimensional fast spin echo sequence using compressed sensing combined with parallel imaging.
Yi, Jisook; Lee, Young Han; Hahn, Seok; Albakheet, Salman S; Song, Ho-Taek; Suh, Jin-Suck.
Afiliação
  • Yi J; Department of Radiology, Research Institute of Radiological Science, YUHS-KRIBB Medical Convergence Research Institute, and Severance Biomedical Science Institute, Yonsei University College of Medicine, Seoul, Republic of Korea.
  • Lee YH; Department of Radiology, Research Institute of Radiological Science, YUHS-KRIBB Medical Convergence Research Institute, and Severance Biomedical Science Institute, Yonsei University College of Medicine, Seoul, Republic of Korea. Electronic address: radiologie@gmail.com.
  • Hahn S; Department of Radiology, Research Institute of Radiological Science, YUHS-KRIBB Medical Convergence Research Institute, and Severance Biomedical Science Institute, Yonsei University College of Medicine, Seoul, Republic of Korea.
  • Albakheet SS; Department of Radiology, Research Institute of Radiological Science, YUHS-KRIBB Medical Convergence Research Institute, and Severance Biomedical Science Institute, Yonsei University College of Medicine, Seoul, Republic of Korea.
  • Song HT; Department of Radiology, Research Institute of Radiological Science, YUHS-KRIBB Medical Convergence Research Institute, and Severance Biomedical Science Institute, Yonsei University College of Medicine, Seoul, Republic of Korea.
  • Suh JS; Department of Radiology, Research Institute of Radiological Science, YUHS-KRIBB Medical Convergence Research Institute, and Severance Biomedical Science Institute, Yonsei University College of Medicine, Seoul, Republic of Korea.
Eur J Radiol ; 112: 52-58, 2019 Mar.
Article em En | MEDLINE | ID: mdl-30777219
ABSTRACT

OBJECTIVES:

To investigate the feasibility of three-dimensional fast spin echo (3D-FSE) imaging with compressed sensing (CS) and parallel imaging (PI) compared to 3D-FSE imaging with only PI in evaluating ankle joint pathologies. MATERIALS AND

METHODS:

Twenty consecutive patients underwent ankle magnetic resonance imaging (MRI), including acquisition of image sets of 2D-FSE sequences, and 3D-FSE sequences without and with CS, between June 2016 and November 2017. Three MR image sets were independently rated by two radiologists for the presence/absence of ankle pathology. Quantitative image similarity and subjective image quality were evaluated using 3D-FSE images without CS and those with CS-PI. Inter-sequence agreement between 3D-FSE sequences without CS and with CS-PI in both readers was evaluated.

RESULTS:

Interobserver agreements were nearly perfect for sprain of the anterior talofibular ligament (ATFL, κ=0.77), osteochondral lesion of the talus (OLT, κ=0.76-0.88), osteochondral lesion of the distal tibia (OLTi, κ=0.74) and os subfibulare (OSF, κ=0.62-0.64). The structural similarity index (mean, 0.996; range, 0.990-0.997) between the 3D-FSE sequences without CS and with CS-PI was acceptable. There was no significant difference in subjective image quality between the two imaging sequences (ATFL, p = 0.317; bone marrow, p = 0.083; cartilage, p = 1.000, tendon, p = 1.000). Intersequence agreement between the 3D-FSE sequences with and without CS was nearly perfect (ATFL and OLTi, κ=1.00; OLT, κ=0.87-0.96; OSF, κ=0.62-0.64) in both readers.

CONCLUSIONS:

Isotropic 3D-FSE ankle MRI with CS provides acceptable diagnostic performance with reduced scan time. Compressed sensing-related artifacts could be minimized with CS reconstruction enhancement, allowing for better image quality for evaluating ankle joint pathologies.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Artropatias / Articulação do Tornozelo Tipo de estudo: Diagnostic_studies / Evaluation_studies Limite: Adult / Female / Humans / Male / Middle aged Idioma: En Revista: Eur J Radiol Ano de publicação: 2019 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Artropatias / Articulação do Tornozelo Tipo de estudo: Diagnostic_studies / Evaluation_studies Limite: Adult / Female / Humans / Male / Middle aged Idioma: En Revista: Eur J Radiol Ano de publicação: 2019 Tipo de documento: Article
...