Your browser doesn't support javascript.
loading
High Failure at a Minimum 5-Year Follow-Up in Primary Total Hip Arthroplasty Using a Modular Femoral Trunnion.
Nahhas, Cindy R; Yi, Paul H; Moric, Mario; Puri, Rajeev; Jacobs, Joshua J; Sporer, Scott M.
Afiliação
  • Nahhas CR; Department of Orthopedic Surgery, Rush University Medical Center, Chicago, IL.
  • Yi PH; Department of Radiology, Johns Hopkins University School of Medicine, Baltimore, MD.
  • Moric M; Department of Orthopedic Surgery, Rush University Medical Center, Chicago, IL.
  • Puri R; Department of Orthopedic Surgery, Riverside Hospital, Kankakee, IL.
  • Jacobs JJ; Department of Orthopedic Surgery, Rush University Medical Center, Chicago, IL.
  • Sporer SM; Department of Orthopedic Surgery, Rush University Medical Center, Chicago, IL.
J Arthroplasty ; 34(7): 1395-1399, 2019 07.
Article em En | MEDLINE | ID: mdl-30982763
ABSTRACT

BACKGROUND:

Modular femoral trunnions enable the surgeon to independently adjust offset, leg length, and anteversion in total hip arthroplasty (THA). However, modularity may result in an increased risk of fretting and corrosion along with a higher risk of implant dissociation or fracture. The purpose of this study is to evaluate mid-term survivorship of THAs using a cementless modular system.

METHODS:

A consecutive series of 221 patients who underwent a primary THA using the ALFA II modular stem by a single surgeon between 2002 and 2004 were reviewed. Survivorship of the ALFA II modular hip system was evaluated at a minimum of 5 years postoperatively.

RESULTS:

Of the 221 patients, 28 (12.7%) died from causes unrelated to the surgery before adequate follow-up, and 64 (29.0%) patients were lost to follow-up. The remaining 129 patients had a mean 6.5-year (range 5-8 years) follow-up. All-cause survivorship of the modular stem system was 81% (95% confidence interval = 69-90) at a mean 6.5-year follow-up. Of the 25 (19.4%) cases requiring revision surgery, 52.0% was for dissociation of the modular components, 32.0% was for fracture of the prosthesis, 12.0% was for instability/multiple dislocations, and 4.0% was for chronic septic THA. Body mass index (odds ratio = 1.080) and offset (odds ratio = 1.254) were independent risk factors for mechanical failures of the modular stem system.

CONCLUSION:

The modular stem hip system of interest in this study demonstrates a high failure rate at mid-term follow-up, and we caution against the use of similar designs in primary THAs.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Desenho de Prótese / Falha de Prótese / Artroplastia de Quadril / Fêmur / Prótese de Quadril Tipo de estudo: Etiology_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Aged / Female / Humans / Male Idioma: En Revista: J Arthroplasty Assunto da revista: ORTOPEDIA Ano de publicação: 2019 Tipo de documento: Article País de afiliação: Israel

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Desenho de Prótese / Falha de Prótese / Artroplastia de Quadril / Fêmur / Prótese de Quadril Tipo de estudo: Etiology_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Aged / Female / Humans / Male Idioma: En Revista: J Arthroplasty Assunto da revista: ORTOPEDIA Ano de publicação: 2019 Tipo de documento: Article País de afiliação: Israel
...