Your browser doesn't support javascript.
loading
Improving the Surgical Effect for Primary Liver Cancer with Intraoperative Fluorescence Navigation Compared with Intraoperative Ultrasound.
Liu, Bing; Liu, Tian; Su, Ming; Ma, Ya-Qi; Zhang, Bei-Feng; Wang, Ye-Fei; Hu, Bing-Yang; Chen, Yong-Liang.
Afiliação
  • Liu B; Department of Hepatobiliary Surgery, Chinese People's Liberation Army (PLA) General Hospital, Beijing, China (mainland).
  • Liu T; Department of Hepatobiliary Surgery, Chinese People's Liberation Army (PLA) General Hospital, Beijing, China (mainland).
  • Su M; Department of Hepatobiliary Surgery, Chinese People's Liberation Army (PLA) General Hospital, Beijing, China (mainland).
  • Ma YQ; Department of Pathology, Chinese People's Liberation Army (PLA) General Hospital, Beijing, China (mainland).
  • Zhang BF; Department of Anesthesia Operation Center, Chinese People's Liberation Army (PLA) General Hospital, Beijing, China (mainland).
  • Wang YF; Department of General Surgery, The First Hospital of Yulin, Yulin, Shaanxi, China (mainland).
  • Hu BY; Department of Hepatobiliary Surgery, Chinese People's Liberation Army (PLA) General Hospital, Beijing, China (mainland).
  • Chen YL; Department of Hepatobiliary Surgery, Chinese People's Liberation Army (PLA) General Hospital, Beijing, China (mainland).
Med Sci Monit ; 25: 3406-3416, 2019 May 08.
Article em En | MEDLINE | ID: mdl-31067211
ABSTRACT
BACKGROUND This study aimed to compare the application value of intraoperative fluorescence navigation technology (FNT) and intraoperative ultrasound (IOUS) in primary liver cancer surgery. MATERIAL AND METHODS Fifty consecutive patients with primary liver cancer scheduled to receive surgical treatment were divided into FNT group and IOUS group. FNT and IOUS were separately used to guide tumor resection and detect new cancerous lesions in the 2 groups. The complete tumor resection rate (R0) resection rate, length of the tumor distance from cutting edge, the diagnostic efficacy of cancerous nodules and the fluorescence imaging characteristics of different types tumors were recorded. RESULTS The R0 resection rate was 100% (25 out of 25 patients) in the FNT group and 96% (24 out of 25 patients) in the IOUS group. In the FNT group, 1 case (4%, 1 out of 25 patients) had cancer tissue that was less than 1 cm from the cutting edge, compared to 7 cases (28%, 7 out of 25 patients) in the IOUS group (P=0.049), which was a significant difference. In the remaining livers of 50 consecutive patients, FNT found 5 new cancerous nodules with a sensitivity of 71.4%, a specificity of 11.1%, and a false-positive rate of 88.9%; for IOUS the results were 42.9%, 88.9%, 11.1%. The fluorescence imaging characteristics of all well-differentiated hepatocellular carcinomas were tumor tissue imaging, but all other types of tumors were ring imaging around the tumor. CONCLUSIONS FNT can improve the R0 resection rate, ensure a safe distance between tumor and cutting edge and can identify more new cancerous nodules compared to IOUS. Thus, FNT could improve the surgical treatment effect for primary liver cancer and hopefully further improve the prognosis of patients.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Monitorização Intraoperatória / Neoplasias Hepáticas Tipo de estudo: Prognostic_studies Limite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Revista: Med Sci Monit Assunto da revista: MEDICINA Ano de publicação: 2019 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Monitorização Intraoperatória / Neoplasias Hepáticas Tipo de estudo: Prognostic_studies Limite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Revista: Med Sci Monit Assunto da revista: MEDICINA Ano de publicação: 2019 Tipo de documento: Article
...