Your browser doesn't support javascript.
loading
A versatile ratiometric electrochemical sensing platform based on N-Mo2C for detection of m-nitrophenol.
Ren, Hailong; Wang, Jingjing; Feng, Huanhuan; Li, Yingchun; Ye, Bang-Ce.
Afiliação
  • Ren H; Key Laboratory for Green Processing of Chemical Engineering of Xinjiang Bingtuan, School of Chemistry and Chemical Engineering, Shihezi University, Shihezi, 832000, China.
  • Wang J; Key Laboratory of Xinjiang Phytomedicine Resources for Ministry of Education, School of Pharmacy, Shihezi University, Shihezi, 832000, China.
  • Feng H; School of Materials Science and Engineering, Harbin Institute of Technology (Shenzhen), Shenzhen, 518055, China. Electronic address: fenghuanhuan@hit.edu.cn.
  • Li Y; Key Laboratory of Xinjiang Phytomedicine Resources for Ministry of Education, School of Pharmacy, Shihezi University, Shihezi, 832000, China; School of Science, Harbin Institute of Technology, Shenzhen, 518055, China. Electronic address: liyingchun@hit.edu.cn.
  • Ye BC; Key Laboratory for Green Processing of Chemical Engineering of Xinjiang Bingtuan, School of Chemistry and Chemical Engineering, Shihezi University, Shihezi, 832000, China; State Key Laboratory of Bioreactor Engineering, East China University of Science and Technology, Shanghai, 200237, China. Electr
Biosens Bioelectron ; 144: 111663, 2019 Nov 01.
Article em En | MEDLINE | ID: mdl-31539721
ABSTRACT
M-nitrophenol (m-NP) is a high priority environmental pollutant and poses a series of threats on human health. Accurate and rapid detection of m-NP in practical samples is very important as this is the key prerequisite for its effective monitoring. Eelectrochemical sensor, though long serving as highly sensitive and fast analytical tool, suffers from the bottleneck problems like low specificity, poor reproducibility, susceptibility to internal and external disturbances, etc. Herein, we developed a ratiometric electrochemical sensor (R-ECS) for m-NP detection, in which nitrogen-doped Mo2C (N-Mo2C) was deployed as the sensing agent and methylene blue (MB) as the internal reference. Full characterization of N-Mo2C was carried out in the aspects of morphology, composition, chemical bonds and electrochemical behavior, and the sensing performance of the easy-to-operate R-ECS was evaluated. Complete separation of the oxidation peaks of m-NP and MB was achieved using the MB/N-Mo2C composite modified electrode and their ratiometric signals were adopted for quantification of m-NP. The linear relation between the electrical signal and the concentration of m-NP is in the range of 1-1500 µM, with the detection limit of 0.256 µM (S/N = 3). The sensor was applied to measure m-NP in real samples from tap water and river. Experimental results demonstrate that it exhibits decent repeatability, reproducibility, stability and selectivity, which proves its great practical potential as an analytical detector.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Água / Técnicas Biossensoriais / Técnicas Eletroquímicas / Nitrofenóis Tipo de estudo: Diagnostic_studies Limite: Humans Idioma: En Revista: Biosens Bioelectron Assunto da revista: BIOTECNOLOGIA Ano de publicação: 2019 Tipo de documento: Article País de afiliação: China

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Água / Técnicas Biossensoriais / Técnicas Eletroquímicas / Nitrofenóis Tipo de estudo: Diagnostic_studies Limite: Humans Idioma: En Revista: Biosens Bioelectron Assunto da revista: BIOTECNOLOGIA Ano de publicação: 2019 Tipo de documento: Article País de afiliação: China
...