Your browser doesn't support javascript.
loading
Site qualification and clinical interpretation standards for 99mTc-SPECT perfusion imaging in a multi-center study of MITNEC (Medical Imaging Trials Network of Canada).
Renaud, Jennifer M; Premaratne, Manuja; Villeneuve, Marie-Claude; Finnerty, Vincent; Harel, Francois; Heinonen, Therèse; Tardif, Jean-Claude; Ruddy, Terrence D; deKemp, Robert A.
Afiliação
  • Renaud JM; Division of Cardiology and National Cardiac PET Centre, University of Ottawa Heart Institute, 40 Ruskin Street, Ottawa, ON, K1Y 4W7, Canada.
  • Premaratne M; Division of Cardiology and National Cardiac PET Centre, University of Ottawa Heart Institute, 40 Ruskin Street, Ottawa, ON, K1Y 4W7, Canada.
  • Villeneuve MC; Peninsula Health Heart Service, Frankston, VIC, Australia.
  • Finnerty V; Monash University, Clayton, VIC, Australia.
  • Harel F; Baker Heart and Diabetes Institute, Melbourne, VIC, Australia.
  • Heinonen T; Division of Cardiology and Montreal Health Innovations Coordinating Centre, Montreal Heart Institute, Montreal, QC, Canada.
  • Tardif JC; Division of Cardiology and Montreal Health Innovations Coordinating Centre, Montreal Heart Institute, Montreal, QC, Canada.
  • Ruddy TD; Division of Cardiology and Montreal Health Innovations Coordinating Centre, Montreal Heart Institute, Montreal, QC, Canada.
  • deKemp RA; Division of Cardiology and Montreal Health Innovations Coordinating Centre, Montreal Heart Institute, Montreal, QC, Canada.
J Nucl Cardiol ; 28(6): 2712-2725, 2021 12.
Article em En | MEDLINE | ID: mdl-32185684
BACKGROUND: Qualification and interpretation standards are essential for establishing 99mTc-SPECT MPI accuracy vs. alternative modalities. METHODS: Rest-stress 99mTc-SPECT phantom scans were acquired on 35 cameras. LV defects were quantified with summed stress (SSS) and difference scores (SDS) at 2 core labs. SDS ≥ 2 in the right coronary artery (RCA) was the qualifying standard. Twenty rest (R)-stress (S) patient images were acquired on qualified cameras and interpreted by core labs. Global scoring differences > 3 between labs or discordant clinical interpretations underwent review. Scoring, interpretation, image quality, and diagnostic parameter agreement were assessed. RESULTS: Phantom scans: visual scoring confirmed RCA-ischemia on all cameras. Regional SSS, SDS agreement was moderate to very good: ICC-r = 0.57, 0.84. Patient scans: 90% of global SSS, 85% of SDS differences were ≤ 3. Regional SSS, SDS agreement: ICC-r = 0.87, 0.86, and global abnormal (SSS ≥ 4) and ischemic (SDS ≥ 2) interpretation: ICC-r = 0.90 were excellent. Clinical interpretation agreement was 100% following review. Image quality agreement was 70%. Automated metrics also agreed: ischemic total perfusion deficit ICC-r = 0.75, reversible perfusion defect, transient ischemic dilation, and S-R LV ejection fraction ICC-r ≥ 0.90. CONCLUSION: Quantitative scoring and interpretation of scans were highly repeatable with site qualification and clinical interpretation standardization, indicating that dual-core lab interpretation is appropriate to determine 99mTc-SPECT MPI accuracy.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Tomografia Computadorizada de Emissão de Fóton Único / Tecnécio / Imagens de Fantasmas / Imagem de Perfusão do Miocárdio Tipo de estudo: Clinical_trials / Guideline Limite: Aged / Aged80 / Female / Humans / Male / Middle aged País/Região como assunto: America do norte Idioma: En Revista: J Nucl Cardiol Assunto da revista: CARDIOLOGIA Ano de publicação: 2021 Tipo de documento: Article País de afiliação: Canadá

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Tomografia Computadorizada de Emissão de Fóton Único / Tecnécio / Imagens de Fantasmas / Imagem de Perfusão do Miocárdio Tipo de estudo: Clinical_trials / Guideline Limite: Aged / Aged80 / Female / Humans / Male / Middle aged País/Região como assunto: America do norte Idioma: En Revista: J Nucl Cardiol Assunto da revista: CARDIOLOGIA Ano de publicação: 2021 Tipo de documento: Article País de afiliação: Canadá
...