Your browser doesn't support javascript.
loading
Automated MRI volumetry as a diagnostic tool for Alzheimer's disease: Validation of icobrain dm.
Struyfs, Hanne; Sima, Diana Maria; Wittens, Melissa; Ribbens, Annemie; Pedrosa de Barros, Nuno; Phan, Thanh Vân; Ferraz Meyer, Maria Ines; Claes, Lene; Niemantsverdriet, Ellis; Engelborghs, Sebastiaan; Van Hecke, Wim; Smeets, Dirk.
Afiliação
  • Struyfs H; icometrix, Leuven, Belgium; Department of Biomedical Sciences, Institute Born-Bunge, University of Antwerp, Antwerp, Belgium.
  • Sima DM; icometrix, Leuven, Belgium. Electronic address: diana.sima@icometrix.com.
  • Wittens M; icometrix, Leuven, Belgium; Department of Biomedical Sciences, Institute Born-Bunge, University of Antwerp, Antwerp, Belgium.
  • Ribbens A; icometrix, Leuven, Belgium.
  • Pedrosa de Barros N; icometrix, Leuven, Belgium.
  • Phan TV; icometrix, Leuven, Belgium.
  • Ferraz Meyer MI; icometrix, Leuven, Belgium; Department of Health Technology, Technical University of Denmark, Lyngby, Denmark.
  • Claes L; icometrix, Leuven, Belgium.
  • Niemantsverdriet E; Department of Biomedical Sciences, Institute Born-Bunge, University of Antwerp, Antwerp, Belgium.
  • Engelborghs S; Department of Biomedical Sciences, Institute Born-Bunge, University of Antwerp, Antwerp, Belgium; Department of Neurology and Center for Neurosciences, UZ Brussel and Vrije Universiteit Brussel (VUB), Brussels, Belgium.
  • Van Hecke W; icometrix, Leuven, Belgium.
  • Smeets D; icometrix, Leuven, Belgium.
Neuroimage Clin ; 26: 102243, 2020.
Article em En | MEDLINE | ID: mdl-32193172
ABSTRACT
Brain volumes computed from magnetic resonance images have potential for assisting with the diagnosis of individual dementia patients, provided that they have low measurement error and high reliability. In this paper we describe and validate icobrain dm, an automatic tool that segments brain structures that are relevant for differential diagnosis of dementia, such as the hippocampi and cerebral lobes. Experiments were conducted in comparison to the widely used FreeSurfer software. The hippocampus segmentations were compared against manual segmentations, with significantly higher Dice coefficients obtained with icobrain dm (25-75th quantiles 0.86-0.88) than with FreeSurfer (25-75th quantiles 0.80-0.83). Other brain structures were also compared against manual delineations, with icobrain dm showing lower volumetric errors overall. Test-retest experiments show that the precision of all measurements is higher for icobrain dm than for FreeSurfer except for the parietal cortex volume. Finally, when comparing volumes obtained from Alzheimer's disease patients against age-matched healthy controls, all measures achieved high diagnostic performance levels when discriminating patients from cognitively healthy controls, with the temporal cortex volume measured by icobrain dm reaching the highest diagnostic performance level (area under the receiver operating characteristic curve = 0.99) in this dataset.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Software / Imageamento por Ressonância Magnética / Interpretação de Imagem Assistida por Computador / Doença de Alzheimer / Neuroimagem Tipo de estudo: Diagnostic_studies / Guideline Limite: Humans Idioma: En Revista: Neuroimage Clin Ano de publicação: 2020 Tipo de documento: Article País de afiliação: Bélgica

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Software / Imageamento por Ressonância Magnética / Interpretação de Imagem Assistida por Computador / Doença de Alzheimer / Neuroimagem Tipo de estudo: Diagnostic_studies / Guideline Limite: Humans Idioma: En Revista: Neuroimage Clin Ano de publicação: 2020 Tipo de documento: Article País de afiliação: Bélgica
...