Your browser doesn't support javascript.
loading
A mm-Sized Free-Floating Wireless Implantable Opto-Electro Stimulation Device.
Jia, Yaoyao; Gong, Yan; Weber, Arthur; Li, Wen; Ghovanloo, Maysam.
Afiliação
  • Jia Y; Department of Electrical and Computer Engineering, North Carolina State University, Raleigh, NC 27606, USA.
  • Gong Y; Department of Electrical and Computer Engineering, Michigan State University, East Lansing, MI 48824, USA.
  • Weber A; Department of Physiology, Michigan State University, East Lansing, MI 48824, USA.
  • Li W; Department of Electrical and Computer Engineering, Michigan State University, East Lansing, MI 48824, USA.
  • Ghovanloo M; Bionic Sciences Inc., Atlanta, GA 30316, USA.
Micromachines (Basel) ; 11(6)2020 Jun 25.
Article em En | MEDLINE | ID: mdl-32630557
ABSTRACT
Towards a distributed neural interface, consisting of multiple miniaturized implants, for interfacing with large-scale neuronal ensembles over large brain areas, this paper presents a mm-sized free-floating wirelessly-powered implantable opto-electro stimulation (FF-WIOS2) device equipped with 16-ch optical and 4-ch electrical stimulation for reconfigurable neuromodulation. The FF-WIOS2 is wirelessly powered and controlled through a 3-coil inductive link at 60 MHz. The FF-WIOS2 receives stimulation parameters via on-off keying (OOK) while sending its rectified voltage information to an external headstage for closed-loop power control (CLPC) via load-shift-keying (LSK). The FF-WIOS2 system-on-chip (SoC), fabricated in a 0.35-µm standard CMOS process, employs switched-capacitor-based stimulation (SCS) architecture to provide large instantaneous current needed for surpassing the optical stimulation threshold. The SCS charger charges an off-chip capacitor up to 5 V at 37% efficiency. At the onset of stimulation, the capacitor delivers charge with peak current in 1.7-12 mA range to a micro-LED (µLED) array for optical stimulation or 100-700 µA range to a micro-electrode array (MEA) for biphasic electrical stimulation. Active and passive charge balancing circuits are activated in electrical stimulation mode to ensure stimulation safety. In vivo experiments conducted on three anesthetized rats verified the efficacy of the two stimulation mechanisms. The proposed FF-WIOS2 is potentially a reconfigurable tool for performing untethered neuromodulation.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Micromachines (Basel) Ano de publicação: 2020 Tipo de documento: Article País de afiliação: Estados Unidos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Micromachines (Basel) Ano de publicação: 2020 Tipo de documento: Article País de afiliação: Estados Unidos
...