Your browser doesn't support javascript.
loading
Toward image quality assessment in optical coherence tomography (OCT) of rat kidney.
Fang, Yuhong; Gong, Wei; Li, Junxia; Li, Weijun; Tan, Jianmin; Xie, Shusen; Huang, Zheng.
Afiliação
  • Fang Y; Key Laboratory of OptoElectronic Science and Technology for Medicine, Ministry of Education, Fujian Provincial Key Laboratory for Photonics Technology, Fujian Normal University, Fuzhou, 350007, China; College of Physics and Information Engineering, Minnan Normal University, Zhangzhou, 363000, China.
  • Gong W; Key Laboratory of OptoElectronic Science and Technology for Medicine, Ministry of Education, Fujian Provincial Key Laboratory for Photonics Technology, Fujian Normal University, Fuzhou, 350007, China.
  • Li J; Department of Nephrology and Medicine, the 900th Hospital of Joint Logistic Support Force, Fuzhou, 350000, China.
  • Li W; Key Laboratory of OptoElectronic Science and Technology for Medicine, Ministry of Education, Fujian Provincial Key Laboratory for Photonics Technology, Fujian Normal University, Fuzhou, 350007, China.
  • Tan J; Department of Nephrology and Medicine, the 900th Hospital of Joint Logistic Support Force, Fuzhou, 350000, China.
  • Xie S; Key Laboratory of OptoElectronic Science and Technology for Medicine, Ministry of Education, Fujian Provincial Key Laboratory for Photonics Technology, Fujian Normal University, Fuzhou, 350007, China. Electronic address: ssxie@fjnu.edu.cn.
  • Huang Z; Key Laboratory of OptoElectronic Science and Technology for Medicine, Ministry of Education, Fujian Provincial Key Laboratory for Photonics Technology, Fujian Normal University, Fuzhou, 350007, China; Department of Electrical Engineering, University of Colorado Denver, CO, USA. Electronic address: z
Photodiagnosis Photodyn Ther ; 32: 101983, 2020 Dec.
Article em En | MEDLINE | ID: mdl-32896630
BACKGROUND: Optical coherence tomography (OCT) is a useful tool for the evaluation of structure and function of the kidney, but the image quality can be effected by many factors. OBJECTIVE: The objective of this study was to assess the image quality of different OCT systems in OCT imaging of the living kidney. METHODS: One swept-source OCT (SSOCT) of 1300 nm, one spectral domain OCT (SDOCT) of 1300 nm and another of 900 nm were used. A FeO phantom was used to establish the point spread function (PSF). Rat kidneys were imaged for image quality assessment. Light penetration in the kidney and the optical attenuation coefficient were also evaluated. The quantification of uriniferous tubules was carried out via the threshold segmentation of 3D OCT images. RESULTS: The quality of kidney images was resolution dependent. SDOCT of 900 nm showed higher peak signal-to noise ratio and dynamic range. The spatial resolution in the light field could be derived from the PSF distribution along three mutually orthogonal axes. In conjunction with the PSF, the Lucy-Richardson algorithm could improve image quality but could not reveal more microstructural information. The penetration depth of 1300 nm was deeper than that of 900 nm. The attenuation coefficient of the kidney was 29 cm-1 at 1300 nm and 50 cm-1 at 900 nm (P < 0.001). More accurate measurement of uriniferous tubules was achieved with the SDOCT-900 due to its higher resolution. CONCLUSIONS: Both SSOCT and SDOCT systems could be useful for imaging uriniferous tubules in the superficial layers of the cortex. The OCT image quality was highly correlated with the spatial resolution of OCT system.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Fotoquimioterapia / Tomografia de Coerência Óptica Limite: Animals Idioma: En Revista: Photodiagnosis Photodyn Ther Assunto da revista: DIAGNOSTICO POR IMAGEM / TERAPEUTICA Ano de publicação: 2020 Tipo de documento: Article País de afiliação: China

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Fotoquimioterapia / Tomografia de Coerência Óptica Limite: Animals Idioma: En Revista: Photodiagnosis Photodyn Ther Assunto da revista: DIAGNOSTICO POR IMAGEM / TERAPEUTICA Ano de publicação: 2020 Tipo de documento: Article País de afiliação: China
...