Your browser doesn't support javascript.
loading
Coding and decoding stray magnetic fields for multiplexing kinetic bioassay platform.
Liu, Yuan; Lin, Gungun; Chen, Yinghui; Mönch, Ingolf; Makarov, Denys; Walsh, Bradley J; Jin, Dayong.
Afiliação
  • Liu Y; Institute for Biomedical Materials and Devices, Faculty of Science, The University of Technology Sydney, Ultimo, New South Wales 2007, Australia. gungun.lin@uts.edu.au dayong.jin@uts.edu.au.
  • Lin G; Institute for Biomedical Materials and Devices, Faculty of Science, The University of Technology Sydney, Ultimo, New South Wales 2007, Australia. gungun.lin@uts.edu.au dayong.jin@uts.edu.au.
  • Chen Y; Institute for Biomedical Materials and Devices, Faculty of Science, The University of Technology Sydney, Ultimo, New South Wales 2007, Australia. gungun.lin@uts.edu.au dayong.jin@uts.edu.au.
  • Mönch I; Institute of Ion Beam Physics and Materials Research, Helmholtz-Zentrum Dresden-Rossendorf e.V, Bautzner Landstrasse 400, 01328, Dresden, Germany.
  • Makarov D; Institute of Ion Beam Physics and Materials Research, Helmholtz-Zentrum Dresden-Rossendorf e.V, Bautzner Landstrasse 400, 01328, Dresden, Germany.
  • Walsh BJ; Minomic International Ltd, Macquarie Park, NSW 2113, Australia.
  • Jin D; Institute for Biomedical Materials and Devices, Faculty of Science, The University of Technology Sydney, Ultimo, New South Wales 2007, Australia. gungun.lin@uts.edu.au dayong.jin@uts.edu.au and UTS-SUStech Joint Research Centre for Biomedical Materials & Devices, Department of Biomedical Enginee
Lab Chip ; 20(24): 4561-4571, 2020 12 15.
Article em En | MEDLINE | ID: mdl-33146648
ABSTRACT
Polymer microspheres can be fluorescently-coded for multiplexing molecular analysis, but their usage has been limited by fluorescent quenching and bleaching and crowded spectral domain with issues of cross-talks and background interference. Each bioassay step of mixing and separation of analytes and reagents require off-line particle handling procedures. Here, we report that stray magnetic fields can code and decode a collection of hierarchically-assembled beads. By the microfluidic assembling of mesoscopic superparamagnetic cores, diverse and non-volatile stray magnetic field response can be built in the series of microscopic spheres, dumbbells, pears, chains and triangles. Remarkably, the set of stray magnetic field fingerprints are readily discerned by a compact giant magnetoresistance sensor for parallelised screening of multiple distinctive pathogenic DNAs. This opens up the magneto-multiplexing opportunity and could enable streamlined assays to incorporate magneto-mixing, washing, enrichment and separation of analytes. This strategy therefore suggests a potential point-of-care testing solution for efficient kinetic assays.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Microfluídica / Campos Magnéticos Idioma: En Revista: Lab Chip Assunto da revista: BIOTECNOLOGIA / QUIMICA Ano de publicação: 2020 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Microfluídica / Campos Magnéticos Idioma: En Revista: Lab Chip Assunto da revista: BIOTECNOLOGIA / QUIMICA Ano de publicação: 2020 Tipo de documento: Article
...