Your browser doesn't support javascript.
loading
Poststudy Point-of-Care Oral Fluid Testing in Human Immunodeficiency Virus-1 Vaccinees.
Oganezova, Karina; Fontana-Martinez, Elvin J; Gothing, Jon A; Pandit, Alisha; Kwara, Esther; Yanosick, Katherine; Dragavon, Joan; Goecker, Erin A; Maenza, Janine; Espy, Nicole; Tomaka, Frank; Lavreys, Ludo; Allen, Mary; D'Souza, Patricia; Hural, John; Coombs, Robert W; Dolin, Raphael; Seaman, Michael S; Walsh, Stephen R; Baden, Lindsey R.
Afiliação
  • Oganezova K; Division of Infectious Diseases, Brigham and Women's Hospital, Boston, Massachusetts, USA.
  • Fontana-Martinez EJ; Division of Infectious Diseases, Brigham and Women's Hospital, Boston, Massachusetts, USA.
  • Gothing JA; Division of Infectious Diseases, Brigham and Women's Hospital, Boston, Massachusetts, USA.
  • Pandit A; Division of Infectious Diseases, Brigham and Women's Hospital, Boston, Massachusetts, USA.
  • Kwara E; Morehouse School of Medicine, Atlanta, Georgia, USA.
  • Yanosick K; Center for Virology and Vaccine Research, Beth Israel Deaconess Medical Center, Boston, Massachusetts, USA.
  • Dragavon J; Department of Laboratory Medicine, University of Washington, Seattle, Washington, USA.
  • Goecker EA; Department of Laboratory Medicine, University of Washington, Seattle, Washington, USA.
  • Maenza J; Vaccine and Infectious Disease Division, Fred Hutchinson Cancer Research Center, Seattle, Washington, USA.
  • Espy N; Department of Medicine, University of Washington, Seattle, Washington, USA.
  • Tomaka F; Vaccine and Infectious Disease Division, Fred Hutchinson Cancer Research Center, Seattle, Washington, USA.
  • Lavreys L; Janssen Pharmaceutical Research and Development, Titusville, New Jersey, USA.
  • Allen M; Janssen Vaccines & Prevention, B.V., Leiden, The Netherlands.
  • D'Souza P; National Institute of Allergy and Infectious Diseases, Rockville, Maryland, USA.
  • Hural J; National Institute of Allergy and Infectious Diseases, Rockville, Maryland, USA.
  • Coombs RW; Vaccine and Infectious Disease Division, Fred Hutchinson Cancer Research Center, Seattle, Washington, USA.
  • Dolin R; Department of Laboratory Medicine, University of Washington, Seattle, Washington, USA.
  • Seaman MS; Department of Medicine, University of Washington, Seattle, Washington, USA.
  • Walsh SR; Center for Virology and Vaccine Research, Beth Israel Deaconess Medical Center, Boston, Massachusetts, USA.
  • Baden LR; Harvard Medical School, Boston, Massachusetts, USA.
Open Forum Infect Dis ; 8(1): ofaa606, 2021 Jan.
Article em En | MEDLINE | ID: mdl-33511233
ABSTRACT

BACKGROUND:

Experimental human immunodeficiency virus (HIV)-1 vaccines frequently elicit antibodies against HIV-1 that may react with commonly used HIV diagnostic tests, a phenomenon known as vaccine-induced seropositivity/seroreactivity (VISP/VISR). We sought to determine, under clinic conditions, whether a patient-controlled HIV test, OraQuick ADVANCE Rapid HIV-1/2 Antibody Test, detected HIV-1 vaccine-induced antibodies.

METHODS:

Plasma assessment of HIV-1 cross-reactivity was examined in end-of-study samples from 57 healthy, HIV-uninfected participants who received a candidate vaccine that has entered Phase 2B and 3 testing. We also screened 120 healthy, HIV-uninfected, unblinded HIV-1 vaccine participants with VISP/VISR for an assessment using saliva. These participants came from 21 different parent vaccine protocols representing 17 different vaccine regimens, all of which contained an HIV-1 envelope immunogen. OraQuick ADVANCE was compared with results from concurrent blood samples using a series of commercial HIV screening immunoassays.

RESULTS:

Fifty-seven unique participant plasma samples were assayed in vitro, and only 1 (1.8%) was reactive by OraQuick ADVANCE. None of the 120 clinic participants (0%; 95% confidence interval, 0% to 3.7%) tested positive by OraQuick ADVANCE, and all were confirmed to be uninfected by HIV-1 viral ribonucleic acid testing. One hundred eighteen of the 120 (98.3%) participants had a reactive HIV test for VISP/VISR 77 (64%) had at least 1 reactive fourth-generation HIV-1 diagnostic test (P < .0001 vs no reactive OraQuick ADVANCE results), and 41 (34%) only had a reactive test by the less specific third-generation Abbott Prism assay.

CONCLUSIONS:

These data suggest that this widely available patient-controlled test has limited reactivity to HIV-1 antibodies elicited by these candidate HIV-1 vaccines.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Guideline Idioma: En Revista: Open Forum Infect Dis Ano de publicação: 2021 Tipo de documento: Article País de afiliação: Estados Unidos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Guideline Idioma: En Revista: Open Forum Infect Dis Ano de publicação: 2021 Tipo de documento: Article País de afiliação: Estados Unidos
...