Optimization of contrast medium volume for abdominal CT in oncologic patients: prospective comparison between fixed and lean body weight-adapted dosing protocols.
Caruso, Damiano; Rosati, Elisa; Panvini, Nicola; Rengo, Marco; Bellini, Davide; Moltoni, Giulia; Bracci, Benedetta; Lucertini, Elena; Zerunian, Marta; Polici, Michela; De Santis, Domenico; Iannicelli, Elsa; Anibaldi, Paolo; Carbone, Iacopo; Laghi, Andrea.
Afiliação
  • Caruso D; Radiology Unit, Department of Surgical and Medical Sciences and Translational Medicine, Sapienza University of Rome - Sant'Andrea University Hospital, Via di Grottarossa, 1035-1039, 00189, Rome, Italy.
  • Rosati E; Radiology Unit, Department of Surgical and Medical Sciences and Translational Medicine, Sapienza University of Rome - Sant'Andrea University Hospital, Via di Grottarossa, 1035-1039, 00189, Rome, Italy.
  • Panvini N; Diagnostic Imaging Unit, Department of Medico-Surgical Sciences and Biotechnologies, ICOT Hospital, "Sapienza" University of Rome, Via Franco Faggiana, 1668, 04100, Latina, Italy.
  • Rengo M; Diagnostic Imaging Unit, Department of Medico-Surgical Sciences and Biotechnologies, ICOT Hospital, "Sapienza" University of Rome, Via Franco Faggiana, 1668, 04100, Latina, Italy.
  • Bellini D; Diagnostic Imaging Unit, Department of Medico-Surgical Sciences and Biotechnologies, ICOT Hospital, "Sapienza" University of Rome, Via Franco Faggiana, 1668, 04100, Latina, Italy.
  • Moltoni G; Radiology Unit, Department of Surgical and Medical Sciences and Translational Medicine, Sapienza University of Rome - Sant'Andrea University Hospital, Via di Grottarossa, 1035-1039, 00189, Rome, Italy.
  • Bracci B; Radiology Unit, Department of Surgical and Medical Sciences and Translational Medicine, Sapienza University of Rome - Sant'Andrea University Hospital, Via di Grottarossa, 1035-1039, 00189, Rome, Italy.
  • Lucertini E; Radiology Unit, Department of Surgical and Medical Sciences and Translational Medicine, Sapienza University of Rome - Sant'Andrea University Hospital, Via di Grottarossa, 1035-1039, 00189, Rome, Italy.
  • Zerunian M; Radiology Unit, Department of Surgical and Medical Sciences and Translational Medicine, Sapienza University of Rome - Sant'Andrea University Hospital, Via di Grottarossa, 1035-1039, 00189, Rome, Italy.
  • Polici M; Radiology Unit, Department of Surgical and Medical Sciences and Translational Medicine, Sapienza University of Rome - Sant'Andrea University Hospital, Via di Grottarossa, 1035-1039, 00189, Rome, Italy.
  • De Santis D; Radiology Unit, Department of Surgical and Medical Sciences and Translational Medicine, Sapienza University of Rome - Sant'Andrea University Hospital, Via di Grottarossa, 1035-1039, 00189, Rome, Italy.
  • Iannicelli E; Radiology Unit, Department of Surgical and Medical Sciences and Translational Medicine, Sapienza University of Rome - Sant'Andrea University Hospital, Via di Grottarossa, 1035-1039, 00189, Rome, Italy.
  • Anibaldi P; Hospital Direction and Clinical Departments, Sant'Andrea University Hospital, Via di Grottarossa, 1035-1039, 00189, Rome, Italy.
  • Carbone I; Diagnostic Imaging Unit, Department of Medico-Surgical Sciences and Biotechnologies, ICOT Hospital, "Sapienza" University of Rome, Via Franco Faggiana, 1668, 04100, Latina, Italy.
  • Laghi A; Radiology Unit, Department of Surgical and Medical Sciences and Translational Medicine, Sapienza University of Rome - Sant'Andrea University Hospital, Via di Grottarossa, 1035-1039, 00189, Rome, Italy. andrea.laghi@uniroma1.it.
Insights Imaging ; 12(1): 40, 2021 Mar 20.
Article em En | MEDLINE | ID: mdl-33743100
ABSTRACT

BACKGROUND:

Patient body size represents the main determinant of parenchymal enhancement and by adjusting the contrast media (CM) dose to patient weight may be a more appropriate approach to avoid a patient over dosage of CM. To compare the performance of fixed-dose and lean body weight (LBW)-adapted contrast media dosing protocols, in terms of image quality and parenchymal enhancement.

RESULTS:

One-hundred cancer patients undergoing multiphasic abdominal CT were prospectively enrolled in this multicentric study and randomly divided in two groups patients in fixed-dose group (n = 50) received 120 mL of CM while in LBW group (n = 50) the amount of CM was computed according to the patient's LBW. LBW protocol group received a significantly lower amount of CM (103.47 ± 17.65 mL vs. 120.00 ± 0.00 mL, p < 0.001). Arterial kidney signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) and pancreatic CNR were significantly higher in LBW group (all p ≤ 0.004). LBW group provided significantly higher arterial liver, kidney, and pancreatic contrast enhancement index (CEI) and portal venous phase kidney CEI (all p ≤ 0.002). Significantly lower portal vein SNR and CNR were observed in LBW-Group (all p ≤ 0.020).

CONCLUSIONS:

LBW-adapted CM administration for abdominal CT reduces the volume of injected CM and improves both image quality and parenchymal enhancement.