Your browser doesn't support javascript.
loading
Novel electronic biosensor for automated inoculum preparation to accelerate antimicrobial susceptibility testing.
Putney, Suzanne; Theiss, Andrew H; Rajan, Nitin K; Deak, Eszter; Buie, Creighton; Ngo, Yvonne; Shah, Hima; Yuan, Victoria; Botbol-Ponte, Elizabeth; Hoyos-Urias, Adrian; Knopfmacher, Oren; Hogan, Catherine A; Banaei, Niaz; Herget, Meike S.
Afiliação
  • Putney S; Avails Medical Inc., 1455 Adams Drive, Menlo Park, CA, 94025, USA.
  • Theiss AH; Avails Medical Inc., 1455 Adams Drive, Menlo Park, CA, 94025, USA.
  • Rajan NK; Avails Medical Inc., 1455 Adams Drive, Menlo Park, CA, 94025, USA.
  • Deak E; Avails Medical Inc., 1455 Adams Drive, Menlo Park, CA, 94025, USA.
  • Buie C; Avails Medical Inc., 1455 Adams Drive, Menlo Park, CA, 94025, USA.
  • Ngo Y; Avails Medical Inc., 1455 Adams Drive, Menlo Park, CA, 94025, USA.
  • Shah H; Avails Medical Inc., 1455 Adams Drive, Menlo Park, CA, 94025, USA.
  • Yuan V; Avails Medical Inc., 1455 Adams Drive, Menlo Park, CA, 94025, USA.
  • Botbol-Ponte E; Avails Medical Inc., 1455 Adams Drive, Menlo Park, CA, 94025, USA.
  • Hoyos-Urias A; Avails Medical Inc., 1455 Adams Drive, Menlo Park, CA, 94025, USA.
  • Knopfmacher O; Avails Medical Inc., 1455 Adams Drive, Menlo Park, CA, 94025, USA.
  • Hogan CA; Stanford University School of Medicine, 3375 Hillview Ave, Palo Alto, CA, 94304, USA.
  • Banaei N; Stanford University School of Medicine, 3375 Hillview Ave, Palo Alto, CA, 94304, USA.
  • Herget MS; Avails Medical Inc., 1455 Adams Drive, Menlo Park, CA, 94025, USA. mherget@availsmedical.com.
Sci Rep ; 11(1): 11360, 2021 05 31.
Article em En | MEDLINE | ID: mdl-34059754
ABSTRACT
A key predictor of morbidity and mortality for patients with a bloodstream infection is time to appropriate antimicrobial therapy. Accelerating antimicrobial susceptibility testing from positive blood cultures is therefore key to improving patient outcomes, yet traditional laboratory approaches can require 2-4 days for actionable results. The eQUANT-a novel instrument utilizing electrical biosensors-produces a standardized inoculum equivalent to a 0.5 McFarland directly from positive blood cultures. This proof-of-concept study demonstrates that eQUANT inocula prepared from clinically significant species of Enterobacterales were comparable to 0.5 McF inocula generated from bacterial colonies in both CFU/ml concentration and performance in antimicrobial susceptibility testing, with ≥ 95% essential and categorical agreement for VITEK2 and disk diffusion. The eQUANT, combined with a rapid, direct from positive blood culture identification technique, can allow the clinical laboratory to begin antimicrobial susceptibility testing using a standardized inoculum approximately 2-3 h after a blood culture flags positive. This has the potential to improve clinical practice by accelerating conventional antimicrobial susceptibility testing and the resulting targeted antibiotic therapy.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Testes de Sensibilidade Microbiana / Eletrônica Tipo de estudo: Diagnostic_studies / Evaluation_studies / Prognostic_studies Idioma: En Revista: Sci Rep Ano de publicação: 2021 Tipo de documento: Article País de afiliação: Estados Unidos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Testes de Sensibilidade Microbiana / Eletrônica Tipo de estudo: Diagnostic_studies / Evaluation_studies / Prognostic_studies Idioma: En Revista: Sci Rep Ano de publicação: 2021 Tipo de documento: Article País de afiliação: Estados Unidos
...