Your browser doesn't support javascript.
loading
Contribution of 18F-FDG PET/CT in the Differential Diagnosis of Pulmonary Hamartomas and Pulmonary Carcinoids
Tatci, Ebru; Özmen, Özlem; Öztürk, Ayperi; Demirag, Funda.
Afiliação
  • Tatci E; University of Health Sciences Turkey, Atatürk Chest Diseases and Thoracic Surgery Training and Research Hospital, Clinic of Nuclear Medicine, Ankara, Turkey
  • Özmen Ö; University of Health Sciences Turkey, Atatürk Chest Diseases and Thoracic Surgery Training and Research Hospital, Clinic of Nuclear Medicine, Ankara, Turkey
  • Öztürk A; University of Health Sciences Turkey, Atatürk Chest Diseases and Thoracic Surgery Training and Research Hospital, Clinic of Interventional Pulmonology, Ankara, Turkey
  • Demirag F; University of Health Sciences Turkey, Atatürk Chest Diseases and Thoracic Surgery Training and Research Hospital, Clinic of Pathology, Ankara, Turkey
Mol Imaging Radionucl Ther ; 30(2): 101-106, 2021 06 03.
Article em En | MEDLINE | ID: mdl-34082511
ABSTRACT

Objectives:

This study aimed to evaluate 18fluorine-fluorodeoxyglucose (18F-FDG) positron emission tomography/computed tomography (PET/CT) findings in the differential diagnosis of pulmonary carcinoids and pulmonary hamartomas.

Methods:

18F-FDG PET/CT findings of 34 patients with pulmonary carcinoids (12 atypical, 22 typical) and 32 patients with pulmonary hamartomas were retrospectively evaluated. Both mean diameter and mean maximum standardized uptake value (SUVmax) of hamartomas and carcinoids were compared by Mann-Whitney U and Kruskall-Wallis H tests.

Results:

The mean longest diameter of atypical carcinoids (3.5±1.7 cm) was higher than that of hamartomas (2.1±1 cm) (p=0.038). No significant difference was found between the mean diameter of typical carcinoids and mean diameter of hamartomas (p=0.128). The mean SUVmax of atypical carcinoids (5.97±3.7) and typical carcinoids (4.22±1.7) were higher than those of hamartomas (1.65±0.9) (p=0.002 and p=0.003, respectively). There were collapse/consolidation in 55.8%, bronchiectasis or mucoid impaction in 47%, and air trapping in 14.7% in the peripheral parenchyma of the 34 carcinoids. Collapse/consolidation was detected in a patient with endobronchial hamartoma, and other finding was not found in the parenchyma around hamartomas.

Conclusion:

The 18F-FDG uptake of pulmonary carcinoids can vary from minimal to intense. 18F-FDG uptake can be seen in pulmonary hamartomas. However, the mean SUVmax of atypical carcinoids and typical carcinoids were higher compared to hamartomas. Pulmonary carcinoid must be suspected in cases with accompanying bronchial obstruction findings in the periphery of the mass.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Diagnostic_studies Idioma: En Revista: Mol Imaging Radionucl Ther Ano de publicação: 2021 Tipo de documento: Article País de afiliação: Turquia