Your browser doesn't support javascript.
loading
Analysis of intact proteins with capillary zone electrophoresis coupled to mass spectromery using uncoated and coated capillaries.
Hamidli, N; Andrasi, M; Nagy, C; Gaspar, A.
Afiliação
  • Hamidli N; Department of Inorganic and Analytical Chemistry, University of Debrecen, Egyetem ter 1, H-4032, Debrecen, Hungary.
  • Andrasi M; Department of Inorganic and Analytical Chemistry, University of Debrecen, Egyetem ter 1, H-4032, Debrecen, Hungary.
  • Nagy C; Department of Inorganic and Analytical Chemistry, University of Debrecen, Egyetem ter 1, H-4032, Debrecen, Hungary.
  • Gaspar A; Department of Inorganic and Analytical Chemistry, University of Debrecen, Egyetem ter 1, H-4032, Debrecen, Hungary. Electronic address: gaspar@science.unideb.hu.
J Chromatogr A ; 1654: 462448, 2021 Sep 27.
Article em En | MEDLINE | ID: mdl-34392123
ABSTRACT
Although, in general, the application of coated capillaries is recommended for the separation of intact proteins, bare silica capillary is still the most often used capillary due to its simplicity and cheapness. In this work, the performance of bare fused silica capillary for intact protein analysis was compared to that of different (dynamically coated polybrene (PB) and permanently coated linear polyacrylamide (LPA)) coated capillaries using capillary zone electrophoresis - mass spectrometry (CZE-MS). In cases where low pH (pH=1.8) was used in bare silica capillaries, good precision (0.56-0.78 RSD% and 1.7-6.5 RSD% for migration times and peak areas, respectively), minimal adsorption and separation efficiency (N= 27 000/m - 322 000/m) similar to or even better than those obtained with the coated capillaries (created by an intricate multi-step process) was achieved. The PB and the LPA capillaries demonstrated their slightly better resolving power in terms of separating the different forms/variants of the same protein (e.g., hemoglobin subunits). Among the studied capillaries the one with LPA coating showed the most stable separations in the long term (n=25 0.18-0.49 RSD% and 3.1-4.9 RSD% for migration times and peak areas, respectively). For the separation of a few proteins or even a larger number of proteins in biological samples (e.g., snake venom) the application of the simple and cheap bare fused silica capillary can be considered as an efficient choice.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Espectrometria de Massas / Proteínas / Técnicas de Química Analítica / Eletroforese Capilar Idioma: En Revista: J Chromatogr A Ano de publicação: 2021 Tipo de documento: Article País de afiliação: Hungria

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Espectrometria de Massas / Proteínas / Técnicas de Química Analítica / Eletroforese Capilar Idioma: En Revista: J Chromatogr A Ano de publicação: 2021 Tipo de documento: Article País de afiliação: Hungria
...