Your browser doesn't support javascript.
loading
Prospective Study of Low- and Standard-dose Chest CT for Pulmonary Nodule Detection: A Comparison of Image Quality, Size Measurements and Radiation Exposure.
Hu, Qiong-Jie; Liu, Yi-Wen; Chen, Chong; Kang, Shi-Chao; Sun, Zi-Yan; Wang, Yu-Jin; Xiang, Min; Xia, Li-Ming; Guan, Han-Xiong.
Afiliação
  • Hu QJ; Department of Radiology, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, 430030, China.
  • Liu YW; Department of Radiology, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, 430030, China.
  • Chen C; Department of Radiology, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, 430030, China.
  • Kang SC; Department of Radiology, Shenzhen Maternity & Child Healthcare Hospital, Southern Medical University, Shenzhen, 518028, China.
  • Sun ZY; Department of Radiology, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, 430030, China.
  • Wang YJ; Department of Radiology, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, 430030, China.
  • Xiang M; Department of Radiology, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, 430030, China.
  • Xia LM; Department of Radiology, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, 430030, China.
  • Guan HX; Department of Radiology, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, 430030, China. hxguan@tjh.tjmu.edu.cn.
Curr Med Sci ; 41(5): 966-973, 2021 Oct.
Article em En | MEDLINE | ID: mdl-34652628
ABSTRACT

OBJECTIVE:

To comprehensively and accurately analyze the out-performance of low-dose chest CT (LDCT) vs. standard-dose CT (SDCT).

METHODS:

The image quality, size measurements and radiation exposure for LDCT and SDCT protocols were evaluated. A total of 117 patients with extra-thoracic malignancies were prospectively enrolled for non-enhanced CT scanning using LDCT and SDCT protocols. Three experienced radiologists evaluated subjective image quality independently using a 5-point score system. Nodule detection efficiency was compared between LDCT and SDCT based on nodule characteristics (size and volume). Radiation metrics and organ doses were analyzed using Radimetrics.

RESULTS:

The images acquired with the LDCT protocol yielded comparable quality to those acquired with the SDCT protocol. The sensitivity of LDCT for the detection of pulmonary nodules (n=650) was lower than that of SDCT (n=660). There was no significant difference in the diameter and volume of pulmonary nodules between LDCT and SDCT (for BMI <22 kg/m2, 4.37 vs. 4.46 mm, and 43.66 vs. 46.36 mm3; for BMI ≥22 kg/m2, 4.3 vs. 4.41 mm, and 41.66 vs. 44.86 mm3) (P>0.05). The individualized volume CT dose index (CTDIvol), the size specific dose estimate and effective dose were significantly reduced in the LDCT group compared with the SDCT group (all P<0.0001). This was especially true for dose-sensitive organs such as the lung (for BMI <22 kg/m2, 2.62 vs. 12.54 mSV, and for BMI ≥22 kg/m2, 1.62 vs. 9.79 mSV) and the breast (for BMI <22 kg/m2, 2.52 vs. 10.93 mSV, and for BMI ≥22 kg/m2, 1.53 vs. 9.01 mSV) (P<0.0001).

CONCLUSION:

These results suggest that with the increases in image noise, LDCT and SDCT exhibited a comparable image quality and sensitivity. The LDCT protocol for chest scans may reduce radiation exposure by about 80% compared to the SDCT protocol.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Intensificação de Imagem Radiográfica / Tomografia Computadorizada por Raios X / Neoplasias Pulmonares Tipo de estudo: Diagnostic_studies / Observational_studies Limite: Adult / Female / Humans / Male / Middle aged Idioma: En Revista: Curr Med Sci Ano de publicação: 2021 Tipo de documento: Article País de afiliação: China

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Intensificação de Imagem Radiográfica / Tomografia Computadorizada por Raios X / Neoplasias Pulmonares Tipo de estudo: Diagnostic_studies / Observational_studies Limite: Adult / Female / Humans / Male / Middle aged Idioma: En Revista: Curr Med Sci Ano de publicação: 2021 Tipo de documento: Article País de afiliação: China
...