Your browser doesn't support javascript.
loading
BandPass: A Bluetooth-Enabled Remote Monitoring Device for Sarcopenia.
Mohieldin, Suehayla; Batsis, John A; Minor, Colin M; Halter, Ryan J; Petersen, Curtis L.
Afiliação
  • Mohieldin S; Thayer School of Engineering, Dartmouth College, Hanover, NH, USA.
  • Batsis JA; Division of Geriatric Medicine, Department of Nutrition, University of North Carolina at Chapel Hill, Chapel Hill, NC, USA.
  • Minor CM; Thayer School of Engineering, Dartmouth College, Hanover, NH, USA.
  • Halter RJ; Thayer School of Engineering, Geisel School of Medicine, Dartmouth College, Hanover, NH, USA.
  • Petersen CL; The Dartmouth Institute for Health Policy and Clinical Practice, Dartmouth College, Hanover, NH, USA.
Article em En | MEDLINE | ID: mdl-34745771
ABSTRACT
As the United States population ages, managing pathologies that largely affect older adults, including sarcopenia (i.e., loss of muscle mass and strength) represents a significant and growing clinical challenge. In addition to increased rates of sarcopenia with age, its incidence and impact increase after acute illness, increasing the risk of functional decline, institutionalization, or death. Resistance-based exercises promote muscle regeneration and strength and are an advised therapy for such patients. Yet, such therapeutic exercises are normally conducted either under direct clinical oversight or unsupervised by patients at home, where compliance rates are low. The presented device, BandPass, aims to create an integrated force data detection and acquisition system for monitoring and transmitting at-home exercise force data to patients and clinicians. A potentiometer-based sensor was integrated to a resistance exercise band through the use of custom designed electronics, which incorporated Bluetooth Low Energy (BLE) for wireless transmission to a mobile 'app'. A protocol for calibrating the device was developed using a range of loads and validated in static benchtop and dynamic testing. Data from a pilot study with 7 older adults was also collected and analyzed to test the device. BandPass is 94% accurate with a coefficient of variation (CoV) of 4.9% and sensitivity of 150g. The pilot study recorded 147 exercises, allowing for analysis on patients' exercise performances. BandPass was successfully able to measure force continuously over time during exercises, measure longitudinal compliance with exercises, and quantify force continuously over time. A mobile health (mHealth) force-sensing system allows for the remote monitoring of prescribed in-home resistance exercise band programs for at-risk older adults, bridging the gap between clinicians and patients.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Guideline Idioma: En Revista: IEEE Int Conf Commun Workshops Ano de publicação: 2021 Tipo de documento: Article País de afiliação: Estados Unidos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Guideline Idioma: En Revista: IEEE Int Conf Commun Workshops Ano de publicação: 2021 Tipo de documento: Article País de afiliação: Estados Unidos
...