Your browser doesn't support javascript.
loading
One-Year Hemodynamic Performance of Three Cardiac Aortic Bioprostheses: A Randomized Comparative Clinical Trial.
Montero-Cruces, Lourdes; Carnero-Alcázar, Manuel; Reguillo-Lacruz, Fernando José; Cobiella-Carnicer, Francisco Javier; Pérez-Camargo, Daniel; Campelos-Fernández, Paula; Maroto-Castellanos, Luis Carlos.
Afiliação
  • Montero-Cruces L; Department of Cardiac Surgery, Cardiovascular Institute, Hospital Clínico San Carlos, 28940 Madrid, Spain.
  • Carnero-Alcázar M; Department of Cardiac Surgery, Cardiovascular Institute, Hospital Clínico San Carlos, 28940 Madrid, Spain.
  • Reguillo-Lacruz FJ; Department of Cardiac Surgery, Cardiovascular Institute, Hospital Clínico San Carlos, 28940 Madrid, Spain.
  • Cobiella-Carnicer FJ; Department of Cardiac Surgery, Cardiovascular Institute, Hospital Clínico San Carlos, 28940 Madrid, Spain.
  • Pérez-Camargo D; Department of Cardiac Surgery, Cardiovascular Institute, Hospital Clínico San Carlos, 28940 Madrid, Spain.
  • Campelos-Fernández P; Department of Cardiac Surgery, Cardiovascular Institute, Hospital Clínico San Carlos, 28940 Madrid, Spain.
  • Maroto-Castellanos LC; Department of Cardiac Surgery, Cardiovascular Institute, Hospital Clínico San Carlos, 28940 Madrid, Spain.
J Clin Med ; 10(22)2021 Nov 16.
Article em En | MEDLINE | ID: mdl-34830622
ABSTRACT

BACKGROUND:

We aimed to compare 1 year the hemodynamic in-vivo performance of three biological aortic prostheses (Carpentier Perimount Magna EaseTM, Crown PRTTM, and TrifectaTM).

METHODS:

The sample used in this study comes from the "BEST-VALVE" clinical trial, which is a phase IV single-blinded randomized clinical trial with the three above-mentioned prostheses.

RESULTS:

154 patients were included. Carpentier Perimount Magna EaseTM (n = 48, 31.2%), Crown PRTTM (n = 51, 32.1%) and TrifectaTM (n = 55, 35.7%). One year after the surgery, the mean aortic gradient and the peak aortic velocity was 17.5 (IQR 11.3-26) and 227.1 (IQR 202.0-268.8) for Carpentier Perimount Magna EaseTM, 21.4 (IQR 14.5-26.7) and 237.8 (IQR 195.9-261.9) for Crown PRTTM, and 13 (IQR 9.6-17.8) and 209.7 (IQR 176.5-241.4) for TrifectaTM, respectively. Pairwise comparisons demonstrated improved mean gradients and maximum velocity of TrifectaTM as compared to Crown PRTTM. Among patients with nominal prosthesis sizes ≤ 21, the mean and peak aortic gradient was higher for Crown PRTTM compared with TrifectaTM, and in patients with an aortic annulus measured with metric Hegar dilators less than or equal to 22 mm.

CONCLUSIONS:

One year after surgery, the three prostheses presented a different hemodynamic performance, being TrifectaTM superior to Crown PRTTM.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Clinical_trials Idioma: En Revista: J Clin Med Ano de publicação: 2021 Tipo de documento: Article País de afiliação: Espanha

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Clinical_trials Idioma: En Revista: J Clin Med Ano de publicação: 2021 Tipo de documento: Article País de afiliação: Espanha
...