Your browser doesn't support javascript.
loading
Troubled Judging of Bronchus Compression Due to Contrast-Filled Balloon in Three-Dimensional Rotational Angiography.
Moerdijk, Anouk S; Breur, Johannes M P J; Molenschot, Mirella M C; Krings, Gregor J.
Afiliação
  • Moerdijk AS; Department of Pediatric Cardiology, Wilhelmina Children's Hospital, University Medical Center Utrecht, P.O. Box 85090, 3508 AB, Utrecht, The Netherlands.
  • Breur JMPJ; Department of Pediatric Cardiology, Wilhelmina Children's Hospital, University Medical Center Utrecht, P.O. Box 85090, 3508 AB, Utrecht, The Netherlands.
  • Molenschot MMC; Department of Pediatric Cardiology, Wilhelmina Children's Hospital, University Medical Center Utrecht, P.O. Box 85090, 3508 AB, Utrecht, The Netherlands.
  • Krings GJ; Department of Pediatric Cardiology, Wilhelmina Children's Hospital, University Medical Center Utrecht, P.O. Box 85090, 3508 AB, Utrecht, The Netherlands. G.Krings@umcutrecht.nl.
Pediatr Cardiol ; 43(3): 704-708, 2022 Mar.
Article em En | MEDLINE | ID: mdl-35034158
ABSTRACT
Three-dimensional rotational angiography (3DRA) is a suitable technique to detect the risk of left main bronchus (LMB) compression during left pulmonary artery (LPA) stenting in partial cavopulmonary connection and total cavopulmonary connection (TCPC). We report on a case of a 4-year-old boy with hypoplastic left heart syndrome and TCPC in which 3DRA and bronchoscopy gave conflicting information on airway patency during balloon interrogation. The balloon with high contrast concentration created a severe artifact impeding visibility of the LMB. Simultaneous flexible bronchoscopy revealed an unobstructed LMB. Repeated 3DRAs with lower contrast concentration had no artifact and showed a patent airway in accordance with the bronchoscopy. Conventional LPA stenting was performed without indication for stent ovalization. The benefit of low contrast concentration in the interrogation balloon was demonstrated in a second case of an 11-year-old boy with TCPC. The margins of the LPA and LMB were clearly visible without blank-out artifact. Oval stent procedure was necessary to prevent LMB compression. When 3DRA is used for vessel-airway interrogation, the balloon contrast concentration should be low in order to avoid artifacts. When in doubt, simultaneous flexible bronchoscopy can overcome the dilemma in airway judgment.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Angiografia / Síndrome do Coração Esquerdo Hipoplásico Limite: Child / Child, preschool / Humans / Male Idioma: En Revista: Pediatr Cardiol Ano de publicação: 2022 Tipo de documento: Article País de afiliação: Holanda

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Angiografia / Síndrome do Coração Esquerdo Hipoplásico Limite: Child / Child, preschool / Humans / Male Idioma: En Revista: Pediatr Cardiol Ano de publicação: 2022 Tipo de documento: Article País de afiliação: Holanda
...