Your browser doesn't support javascript.
loading
Clinical outcomes of a beveled tip, ultra-high speed, 25-gauge pars plana vitrectomy system.
Uy, Harvey S; Cabahug, Vicente Lorenzo O; Artiaga, Jose Carlo M; Chan, Pik Sha; Famadico, Jordan T.
Afiliação
  • Uy HS; Peregrine Eye and Laser Institute, Morning Star Center, 347 Gil Puyat Avenue, Bel Air, 1209, Makati City, Philippines. harveyuy@yahoo.com.
  • Cabahug VLO; Department of Ophthalmology and Visual Sciences, University of the Philippines, Manila, Philippines. harveyuy@yahoo.com.
  • Artiaga JCM; Eye Institute, St Luke's Medical Center, Quezon City, Philippines. harveyuy@yahoo.com.
  • Chan PS; Cebu Doctors' University Hospital, Cebu City, Philippines.
  • Famadico JT; Moorfields Eye Hospital NHS Foundation Trust, London, UK.
BMC Ophthalmol ; 22(1): 93, 2022 Feb 24.
Article em En | MEDLINE | ID: mdl-35196996
ABSTRACT

OBJECTIVE:

To report the clinical outcomes of a 25-gauge, beveled-tip, 10,000 cuts-per-minute (cpm) microincisional vitrectomy surgery (MIVS) system.

METHODS:

Prospective case series of eyes undergoing primary pars plana vitrectomy (PPV) for common vitreoretinal indications. Main outcome measures were rate of achieving surgical objectives, operative times, number of surgical steps, use of ancillary instruments, corrected distance visual acuity (CDVA), and adverse events (AE).

RESULTS:

The surgical objectives were achieved in all eyes. Mean total operative time (TOT), core, shave and total vitrectomy times were 1891 ± 890, 204 ± 120, 330 ± 320, 534 ± 389 s, respectively. Mean number of surgical steps was 4.3 ± 1.5. Mean number of ancillary instruments used was 4.5 ± 1.9. Mean CDVA improved by 0.53 ± 0.56 logMAR units (P < 0.001) 3 months postoperatively. AE included elevated IOP (8%), hypotony (6%), and re-detachment (2%). Majority (82%) had no postoperative discomfort. The number of surgical steps demonstrated a positive correlation with TOT (p < 0.05), number of ancillary instruments used (p < 0.05), and postoperative Day 1 IOP (p < 0.05). The number of times ancillary instrumentation was used demonstrated a positive correlation with TOT (p < 0.05).

CONCLUSION:

Beveled-tip, 10,000 cpm MIVS system effectively and safely performs common VR procedures of varying complexity and may reduce operative times and use of ancillary instrumentation.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Vitrectomia / Glaucoma Tipo de estudo: Observational_studies Limite: Humans Idioma: En Revista: BMC Ophthalmol Assunto da revista: OFTALMOLOGIA Ano de publicação: 2022 Tipo de documento: Article País de afiliação: Filipinas

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Vitrectomia / Glaucoma Tipo de estudo: Observational_studies Limite: Humans Idioma: En Revista: BMC Ophthalmol Assunto da revista: OFTALMOLOGIA Ano de publicação: 2022 Tipo de documento: Article País de afiliação: Filipinas
...