Your browser doesn't support javascript.
loading
Comparison of Synthetic Computed Tomography Generation Methods, Incorporating Male and Female Anatomical Differences, for Magnetic Resonance Imaging-Only Definitive Pelvic Radiotherapy.
O'Connor, Laura M; Choi, Jae H; Dowling, Jason A; Warren-Forward, Helen; Martin, Jarad; Greer, Peter B.
Afiliação
  • O'Connor LM; Department of Radiation Oncology, Calvary Mater Hospital, Newcastle, NSW, Australia.
  • Choi JH; School of Health Sciences, University of Newcastle, Callaghan, NSW, Australia.
  • Dowling JA; Department of Radiation Oncology, Calvary Mater Hospital, Newcastle, NSW, Australia.
  • Warren-Forward H; School of Mathematical and Physical Sciences, University of Newcastle, Callaghan, NSW, Australia.
  • Martin J; Commonwealth Scientific and Industrial Research Organisation (CSIRO), Australian E-Health Research Centre, Herston, QLD, Australia.
  • Greer PB; School of Health Sciences, University of Newcastle, Callaghan, NSW, Australia.
Front Oncol ; 12: 822687, 2022.
Article em En | MEDLINE | ID: mdl-35211413
PURPOSE: There are several means of synthetic computed tomography (sCT) generation for magnetic resonance imaging (MRI)-only planning; however, much of the research omits large pelvic treatment regions and female anatomical specific methods. This research aimed to apply four of the most popular methods of sCT creation to facilitate MRI-only radiotherapy treatment planning for male and female anorectal and gynecological neoplasms. sCT methods were validated against conventional computed tomography (CT), with regard to Hounsfield unit (HU) estimation and plan dosimetry. METHODS AND MATERIALS: Paired MRI and CT scans of 40 patients were used for sCT generation and validation. Bulk density assignment, tissue class density assignment, hybrid atlas, and deep learning sCT generation methods were applied to all 40 patients. Dosimetric accuracy was assessed by dose difference at reference point, dose volume histogram (DVH) parameters, and 3D gamma dose comparison. HU estimation was assessed by mean error and mean absolute error in HU value between each sCT and CT. RESULTS: The median percentage dose difference between the CT and sCT was <1.0% for all sCT methods. The deep learning method resulted in the lowest median percentage dose difference to CT at -0.03% (IQR 0.13, -0.31) and bulk density assignment resulted in the greatest difference at -0.73% (IQR -0.10, -1.01). The mean 3D gamma dose agreement at 3%/2 mm among all sCT methods was 99.8%. The highest agreement at 1%/1 mm was 97.3% for the deep learning method and the lowest was 93.6% for the bulk density method. Deep learning and hybrid atlas techniques gave the lowest difference to CT in mean error and mean absolute error in HU estimation. CONCLUSIONS: All methods of sCT generation used in this study resulted in similarly high dosimetric agreement for MRI-only planning of male and female cancer pelvic regions. The choice of the sCT generation technique can be guided by department resources available and image guidance considerations, with minimal impact on dosimetric accuracy.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Guideline Idioma: En Revista: Front Oncol Ano de publicação: 2022 Tipo de documento: Article País de afiliação: Austrália

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Guideline Idioma: En Revista: Front Oncol Ano de publicação: 2022 Tipo de documento: Article País de afiliação: Austrália
...