Your browser doesn't support javascript.
loading
Sustainable liquid chromatographic determination and purity assessment of a possible add-on triple-action over-the-counter pharmaceutical combination in COVID-19.
Marzouk, Hoda M; Ibrahim, Engy A; Hegazy, Maha A; Saad, Samah S.
Afiliação
  • Marzouk HM; Analytical Chemistry Department, Faculty of Pharmacy, Cairo University, Kasr Al-Aini Street, 11562, Cairo, Egypt.
  • Ibrahim EA; Pharmaceutical Analytical Chemistry Department, College of Pharmaceutical Sciences and Drug Manufacturing, Misr University for Science & Technology, 6 of October City, Giza, Egypt.
  • Hegazy MA; Analytical Chemistry Department, Faculty of Pharmacy, Cairo University, Kasr Al-Aini Street, 11562, Cairo, Egypt.
  • Saad SS; Pharmaceutical Analytical Chemistry Department, College of Pharmaceutical Sciences and Drug Manufacturing, Misr University for Science & Technology, 6 of October City, Giza, Egypt.
Microchem J ; 178: 107400, 2022 Jul.
Article em En | MEDLINE | ID: mdl-35341079
ABSTRACT
Nowadays, all researchers are focused on combating the pandemic COVID-19. According to recent statistics, most patients are managed at home. An over-the-counter (OTC) triple action formula containing paracetamol (PAR), aspirin (ASP), and diphenhydramine (DIPH) is widely prescribed for pain, fever and as night-time sleep aid. For COVID-19 patients, this combination is now suggested as part of symptomatic therapy and prophylaxis. In this work, two simple liquid chromatographic approaches were designed for simultaneous determination of PAR, ASP, and DIPH in Excedrin® PM caplets, beside three specified official toxic impurities, namely, p-aminophenol, p-nitrophenol, and salicylic acid. The first method comprised high-performance thin-layer chromatographic separation coupled with densitometric quantification, on silica gel HPTLC 60 F254 aluminium sheets as the stationary phase, ethyl acetate-methanol-aqueous ammonium hydroxide (10.0 2.0 0.1, by volume) as the developing system and scanning was performed at 210.0 nm. The second one is a high-performance liquid chromatography coupled with diode array detector. Successful separation of the six components was performed on XTerra C18 column with isocratic elution of mobile phase 0.1% triethylamine acidified water methanol (7030, v/v) adjusted with o-phosphoric acid to pH 3.0 and methanol (9010, v/v) with flow rate programming and detection at 210.0 nm. Validation of the proposed methods was performed according to ICH guidelines. Both methods were successfully used for quality control of the cited drugs in their marketed formulation. Moreover, the in-vitro release study was monitored using the proposed HPLC-DAD method. The greenness profile of the proposed methods was assessed and comparatively evaluated through various assessment tools, specifically; the analytical eco-scale system, national environmental method index (NEMI), green analytical procedure index (GAPI) and analytical greenness (AGREE) metric.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Guideline Idioma: En Revista: Microchem J Ano de publicação: 2022 Tipo de documento: Article País de afiliação: Egito

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Guideline Idioma: En Revista: Microchem J Ano de publicação: 2022 Tipo de documento: Article País de afiliação: Egito
...