Your browser doesn't support javascript.
loading
A high-speed radiation imaging system based on liquid scintillator filled capillary arrays.
Song, Y; Zhang, M; Duan, B J; Yan, W P; Sheng, L; Song, G Z; Ma, J M; Han, C C; Yao, Z M.
Afiliação
  • Song Y; State Key Laboratory of Intense Pulsed Radiation Simulation and Effect, Northwest Institute of Nuclear Technology, Xi'an, China.
  • Zhang M; State Key Laboratory of Intense Pulsed Radiation Simulation and Effect, Northwest Institute of Nuclear Technology, Xi'an, China.
  • Duan BJ; State Key Laboratory of Intense Pulsed Radiation Simulation and Effect, Northwest Institute of Nuclear Technology, Xi'an, China.
  • Yan WP; State Key Laboratory of Intense Pulsed Radiation Simulation and Effect, Northwest Institute of Nuclear Technology, Xi'an, China.
  • Sheng L; State Key Laboratory of Intense Pulsed Radiation Simulation and Effect, Northwest Institute of Nuclear Technology, Xi'an, China.
  • Song GZ; State Key Laboratory of Intense Pulsed Radiation Simulation and Effect, Northwest Institute of Nuclear Technology, Xi'an, China.
  • Ma JM; State Key Laboratory of Intense Pulsed Radiation Simulation and Effect, Northwest Institute of Nuclear Technology, Xi'an, China.
  • Han CC; State Key Laboratory of Intense Pulsed Radiation Simulation and Effect, Northwest Institute of Nuclear Technology, Xi'an, China.
  • Yao ZM; State Key Laboratory of Intense Pulsed Radiation Simulation and Effect, Northwest Institute of Nuclear Technology, Xi'an, China.
Rev Sci Instrum ; 93(3): 033702, 2022 Mar 01.
Article em En | MEDLINE | ID: mdl-35365019
ABSTRACT
A high-speed radiation imaging system based on an image converter of liquid scintillator filled capillary arrays has been developed, which is sensitive to x rays, gamma rays, and neutrons. This imaging system has advantages of both high spatial resolution and high sensitivity because increasing the thickness of the image converter only leads to little deterioration on imaging resolution. The capillary arrays have dimensions of 150 mm diameter and 50 mm thickness, with 100 µm diameter of each capillary. The fluorescence decay time of the filled liquid scintillator based on the mixture of p-xylene and 2,5-diphenyloxazole has been evaluated to be ∼3 ns with the single photon method under the gamma ray excitation. The spatial resolution has been experimentally evaluated to be about 1.15 and 0.6 mm, under excitation of x rays and neutrons, respectively. The imaging system has been applied for diagnosing the dynamic x-ray spot generated by the rod pinch. Two frames in single shot with 15 ns temporal resolution and 20 ns inter-frame separation time have been obtained, which show the spatiotemporal distribution of the electrons bombarding the tungsten rod, indicating the ability of this imaging system in diagnosing dynamic radiation objects. In addition, the technique of capillary arrays provides a promising path for applications of advanced liquid scintillators in the field of radiation imaging.

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Rev Sci Instrum Ano de publicação: 2022 Tipo de documento: Article País de afiliação: China

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Rev Sci Instrum Ano de publicação: 2022 Tipo de documento: Article País de afiliação: China
...