Effects of 5.8 GHz Microwaves on Testicular Structure and Function in Rats.
Biomed Res Int
; 2022: 5182172, 2022.
Article
em En
| MEDLINE
| ID: mdl-35707372
ABSTRACT
Objective:
To investigate the effects of exposure to 5.8 GHz microwaves on testicular structure and function of male adult rats.Methods:
After 30 days of exposure, we evaluated sperm quality by determining sperm concentration and quantifying the number of abnormal sperm. Testicular morphology was investigated by hematoxylin-eosin (HE) staining. The levels of testosterone (T), follicle-stimulating hormone (FSH), luteinizing hormone (LH), glial cell line-derived neurotrophic factor (GDNF), stem cell factor (SCF), and transferrin (TRF) were determined by enzyme-linked immunosorbent assays (ELISAs). We also used western blotting to determine the levels of GDNF and SCF and apoptosis-related protein (caspase-3) in the testis.Results:
Compared with the sham group, there were no significant differences in terms of sperm count, sperm abnormality, and the levels of T, FSH, LH, GDNF, SCF, and caspase-3 in the microwave group.Conclusion:
Under the experimental conditions, 5.8 GHz microwave exposure has no obvious effect on testicular structure and function of rats.
Texto completo:
1
Coleções:
01-internacional
Base de dados:
MEDLINE
Assunto principal:
Testículo
/
Micro-Ondas
Limite:
Animals
Idioma:
En
Revista:
Biomed Res Int
Ano de publicação:
2022
Tipo de documento:
Article
País de afiliação:
China