Your browser doesn't support javascript.
loading
Voltammetric Determination of Hg2+, Zn2+, and Pb2+ Ions Using a PEDOT/NTA-Modified Electrode.
Alshawi, Jasim M S; Mohammed, Mohammed Q; Alesary, Hasan F; Ismail, Hani K; Barton, Stephen.
Afiliação
  • Alshawi JMS; Department of Chemistry, College of Education for Pure Sciences, University of Basrah, Basrah 61001, Iraq.
  • Mohammed MQ; Department of Chemistry, College of Education for Pure Sciences, University of Basrah, Basrah 61001, Iraq.
  • Alesary HF; Department of Chemistry, College of Science, University of Kerbala, Karbala 56001, Iraq.
  • Ismail HK; Department of Chemistry, Faculty of Science and Health, Koya University, Koya KOY45, Kurdistan Region - F.R., Iraq.
  • Barton S; School of Life Sciences, Pharmacy and Chemistry, Kingston University London, Kingston-Upon-Thames KT1 1LQ, Surrey, U.K.
ACS Omega ; 7(23): 20405-20419, 2022 Jun 14.
Article em En | MEDLINE | ID: mdl-35722009
ABSTRACT
A novel electrochemical sensor for determining trace levels of Hg2+, Pb2+, and Zn2+ ions in water using square wave voltammetry (SWV) is reported. The sensor is based on a platinum electrode (Pt) modified by poly(3,4-ethylenedioxythiophene) and N α,N α-bis-(carboxymethyl)-l-lysine hydrate (NTA lysine) PEDOT/NTA. The modified electrode surface (PEDOT/NTA) was prepared via the introduction of the lysine-NTA group to a PEDOT/N-hydroxyphthalimide NHP electrode. The (PEDOT/NTA) was characterized via cyclic voltammetry (CV), Fourier transform infrared (FTIR) spectroscopy, and scanning electron microscopy (SEM). The effects of scan rates on the electrochemical properties of the polymer electrode were also investigated. The electrochemical results were used to estimate the coverage of the electrode polymer surface and its electrostability in background electrolyte solutions. Several analytical parameters, such as polymer film thickness, metal deposition time, and pH of the electrolyte, were examined. Linear responses to Hg2+, Pb2+, and Zn2+ ions in the concentration range of 5-100 µg L-1 were obtained. The limits of detection (LODs) for the determination of Hg2+, Pb2+, and Zn2+ ions were 1.73, 2.33, and 1.99 µg L-1, respectively. These promising results revealed that modified PEDOT/NTA films might well represent an important addition to existing electrochemical sensor technologies.

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: ACS Omega Ano de publicação: 2022 Tipo de documento: Article País de afiliação: Iraque

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: ACS Omega Ano de publicação: 2022 Tipo de documento: Article País de afiliação: Iraque
...