Your browser doesn't support javascript.
loading
On the analysis of data augmentation methods for spectral imaged based heart sound classification using convolutional neural networks.
Zhou, George; Chen, Yunchan; Chien, Candace.
Afiliação
  • Zhou G; Weill Cornell Medicine, New York, NY, 10021, USA. gez4001@med.cornell.edu.
  • Chen Y; Weill Cornell Medicine, New York, NY, 10021, USA.
  • Chien C; Weill Cornell Medicine, New York, NY, 10021, USA.
BMC Med Inform Decis Mak ; 22(1): 226, 2022 08 29.
Article em En | MEDLINE | ID: mdl-36038901
BACKGROUND: The application of machine learning to cardiac auscultation has the potential to improve the accuracy and efficiency of both routine and point-of-care screenings. The use of convolutional neural networks (CNN) on heart sound spectrograms in particular has defined state-of-the-art performance. However, the relative paucity of patient data remains a significant barrier to creating models that can adapt to a wide range of potential variability. To that end, we examined a CNN model's performance on automated heart sound classification, before and after various forms of data augmentation, and aimed to identify the most optimal augmentation methods for cardiac spectrogram analysis. RESULTS: We built a standard CNN model to classify cardiac sound recordings as either normal or abnormal. The baseline control model achieved a PR AUC of 0.763 ± 0.047. Among the single data augmentation techniques explored, horizontal flipping of the spectrogram image improved the model performance the most, with a PR AUC of 0.819 ± 0.044. Principal component analysis color augmentation (PCA) and perturbations of saturation-value (SV) of the hue-saturation-value (HSV) color scale achieved a PR AUC of 0.779 ± 045 and 0.784 ± 0.037, respectively. Time and frequency masking resulted in a PR AUC of 0.772 ± 0.050. Pitch shifting, time stretching and compressing, noise injection, vertical flipping, and applying random color filters negatively impacted model performance. Concatenating the best performing data augmentation technique (horizontal flip) with PCA and SV perturbations improved model performance. CONCLUSION: Data augmentation can improve classification accuracy by expanding and diversifying the dataset, which protects against overfitting to random variance. However, data augmentation is necessarily domain specific. For example, methods like noise injection have found success in other areas of automated sound classification, but in the context of cardiac sound analysis, noise injection can mimic the presence of murmurs and worsen model performance. Thus, care should be taken to ensure clinically appropriate forms of data augmentation to avoid negatively impacting model performance.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Ruídos Cardíacos Limite: Humans Idioma: En Revista: BMC Med Inform Decis Mak Assunto da revista: INFORMATICA MEDICA Ano de publicação: 2022 Tipo de documento: Article País de afiliação: Estados Unidos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Ruídos Cardíacos Limite: Humans Idioma: En Revista: BMC Med Inform Decis Mak Assunto da revista: INFORMATICA MEDICA Ano de publicação: 2022 Tipo de documento: Article País de afiliação: Estados Unidos
...