TECHNIQUE FOR REMOVAL OF A GANCICLOVIR IMPLANT DISLOCATED IN THE VITREOUS CAVITY.
Retin Cases Brief Rep
; 18(1): 91-93, 2024 Jan 01.
Article
em En
| MEDLINE
| ID: mdl-36067423
ABSTRACT
PURPOSE:
To report a technique to remove a dislocated ganciclovir implant in the vitreous cavity.METHODS:
Retrospective case series. Two patients with dislocated ganciclovir implants in the vitreous cavity.RESULTS:
A 6-mm pars plana incision was made; the soft tip was used to elevate the implant behind the intraocular lens and then 0.12-mm forceps were used to externalize the implant. The implant was successfully removed in both patients.CONCLUSION:
Removal of a dislocated ganciclovir implant with its encasing strut can be effectively retrieved using a bimanual approach.