Detecting low-intake dehydration using bioelectrical impedance analysis in older adults in acute care settings: a systematic review.
Alsanie, Saleh; Lim, Stephen; Wootton, Stephen A.
Afiliação
  • Alsanie S; School of Human Development and Health, Faculty of Medicine, University of Southampton, Southampton, UK.
  • Lim S; Department of Clinical Nutrition, College of Applied Health Sciences in Arrass, Qassim University, Buraydah, Saudi Arabia.
  • Wootton SA; NIHR Southampton Biomedical Research Centre, University of Southampton and University Hospital Southampton NHS Trust, Southampton, UK.
BMC Geriatr ; 22(1): 954, 2022 12 12.
Article em En | MEDLINE | ID: mdl-36510185
ABSTRACT

BACKGROUND:

Dehydration is a frequent cause of excess morbidity and poor health outcomes, particularly in older adults who have an increased risk of fluid loss due to renal senescence, comorbidities, and polypharmacy. Detecting dehydration is key to instigating treatment to resolve the problem and prevent further adverse consequences; however, current approaches to diagnosis are unreliable and, as a result, under-detection remains a widespread problem. This systematic review sought to explore the value of bioelectrical impedance in detecting low-intake dehydration among older adults admitted to acute care settings.

METHODS:

A literature search using MEDLINE, EMBASE, CINAHL, Web of Science, and the Cochrane Library was undertaken from inception till May 2022 and led to the eventual evaluation of four studies. Risk of bias was assessed using the Cochrane tool for observational studies; three studies had a high risk of bias, and one had a low risk. Data were extracted using systematic proofs. Due to insufficient reporting, the data were analysed using narrative synthesis.

RESULTS:

One study showed that the sensitivity and specificity of bioelectrical impedance in detecting low-intake dehydration varied considerably depending on the total body water percentage threshold used to ascertain dehydration status. Other included studies supported the technique's utility when compared to conventional measures of hydration status.

CONCLUSIONS:

Given the scarcity of literature and inconsistency between findings, it is not possible to ascertain the value of bioelectrical impedance for detecting low-intake dehydration in older inpatients.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Desidratação / Hospitalização Tipo de estudo: Diagnostic_studies / Etiology_studies / Observational_studies / Systematic_reviews Limite: Aged / Humans Idioma: En Revista: BMC Geriatr Assunto da revista: GERIATRIA Ano de publicação: 2022 Tipo de documento: Article País de afiliação: Reino Unido

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Desidratação / Hospitalização Tipo de estudo: Diagnostic_studies / Etiology_studies / Observational_studies / Systematic_reviews Limite: Aged / Humans Idioma: En Revista: BMC Geriatr Assunto da revista: GERIATRIA Ano de publicação: 2022 Tipo de documento: Article País de afiliação: Reino Unido
...