Your browser doesn't support javascript.
loading
Exploring the performance of quadrupole, time-of-flight, and multi-collector ICP-MS for dual-isotope detection on single nanoparticles and cells.
Tian, Xiangwei; Jiang, Haowen; Wang, Meng; Cui, Wenbin; Guo, Yingying; Zheng, Lingna; Hu, Ligang; Qu, Guangbo; Yin, Yongguang; Cai, Yong; Jiang, Guibin.
Afiliação
  • Tian X; Laboratory of Environmental Nanotechnology and Health Effect, Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing, 100085, China; State Key Laboratory of Environmental Chemistry and Ecotoxicology, Research Center for Eco-Environmental Sciences, Chinese Academy of Sci
  • Jiang H; Laboratory of Environmental Nanotechnology and Health Effect, Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing, 100085, China; State Key Laboratory of Environmental Chemistry and Ecotoxicology, Research Center for Eco-Environmental Sciences, Chinese Academy of Sci
  • Wang M; CAS Key Laboratory for Biomedical Effects of Nanomaterials and Nanosafety, Institute of High Energy Physics, Chinese Academy of Sciences, Beijing, 100049, China.
  • Cui W; R&D Center, Shandong Yingsheng Biotechnology Co., Ltd., Beijing, 100088, China.
  • Guo Y; Laboratory of Environmental Nanotechnology and Health Effect, Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing, 100085, China; State Key Laboratory of Environmental Chemistry and Ecotoxicology, Research Center for Eco-Environmental Sciences, Chinese Academy of Sci
  • Zheng L; CAS Key Laboratory for Biomedical Effects of Nanomaterials and Nanosafety, Institute of High Energy Physics, Chinese Academy of Sciences, Beijing, 100049, China.
  • Hu L; State Key Laboratory of Environmental Chemistry and Ecotoxicology, Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing, 100085, China.
  • Qu G; State Key Laboratory of Environmental Chemistry and Ecotoxicology, Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing, 100085, China.
  • Yin Y; Laboratory of Environmental Nanotechnology and Health Effect, Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing, 100085, China; State Key Laboratory of Environmental Chemistry and Ecotoxicology, Research Center for Eco-Environmental Sciences, Chinese Academy of Sci
  • Cai Y; Laboratory of Environmental Nanotechnology and Health Effect, Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing, 100085, China; State Key Laboratory of Environmental Chemistry and Ecotoxicology, Research Center for Eco-Environmental Sciences, Chinese Academy of Sci
  • Jiang G; State Key Laboratory of Environmental Chemistry and Ecotoxicology, Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing, 100085, China.
Anal Chim Acta ; 1240: 340756, 2023 Feb 01.
Article em En | MEDLINE | ID: mdl-36641141
ABSTRACT
To meet the demand for multi-element/isotope analysis at the single nanoparticle (NP) or cell level, different types of inductively coupled plasma mass spectroscopy (ICP-MS) have been used to simultaneously monitor multiple mass-to-charge ratios in single-particle/cell ICP-MS (SP/SC-ICP-MS) analysis. Systematic evaluation and comparison of the performance of these techniques are urgently required. Herein, three ICP-quadrupole (Q)-MS, two ICP-time of flight (TOF)-MS, and one multi-collector (MC)-ICP-MS instruments were employed to simultaneously detect 107Ag and 109Ag on single Ag NPs and Ag-exposed cyanobacteria cells. The evaluation was conducted by comparing the measured event-specific 109Ag107Ag ratios with the natural ratio. Duration of NP or cell events and time resolution in the peak hopping mode were the main factors affecting the performance of ICP-Q-MS. Under the optimal condition (100 µs for both dwell time and settling time), less than 45% of the NP or cell events had a 109Ag107Ag ratio deviating <30% from the natural ratio. Most events obtained via ICP-TOF-MS were paired events with both isotopes detected. For large-size NPs and cells with high exposure levels, nearly 80% of the events had a ratio deviation within ±30%. MC-ICP-MS performed particularly well in isotope determination with all the events having a ratio deviation within ±5%. For ICP-TOF-MS and MC-ICP-MS, the signal intensity of the events was the main factor affecting the accuracy of the measured 109Ag107Ag ratios due to the counting statistics. The established methods and results provide insight on the analyses of two elements/isotopes or more on single NPs or cells. Based on the comparison of the advantages and limitations of these instruments, this study provides a critical reference for future multi-element/isotope SP/SC-ICP-MS analyses.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Nanopartículas Tipo de estudo: Diagnostic_studies Idioma: En Revista: Anal Chim Acta Ano de publicação: 2023 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Nanopartículas Tipo de estudo: Diagnostic_studies Idioma: En Revista: Anal Chim Acta Ano de publicação: 2023 Tipo de documento: Article
...