Your browser doesn't support javascript.
loading
A Quantitative Method for the Composition of 7B05 Cast-Rolled Aluminum Alloys Based on Micro-Beam X-ray Fluorescence Spectroscopy and Its Application in Element Segregation of Recrystallization.
Dong, Caichang; Sun, Dandan; Li, Dongling; Yang, Wanguo; Wang, Haizhou; Wan, Weihao; Yan, Zun.
Afiliação
  • Dong C; Qingdao NCS Testing & Corrosion Protection Technology Co., Ltd., Qingdao 266071, China.
  • Sun D; National Observation & Research Station on Materials Corrosion in Marine and Atmospheric Environment in Qingdao, Qingdao 266071, China.
  • Li D; Qingdao NCS Testing & Corrosion Protection Technology Co., Ltd., Qingdao 266071, China.
  • Yang W; National Observation & Research Station on Materials Corrosion in Marine and Atmospheric Environment in Qingdao, Qingdao 266071, China.
  • Wang H; Beijing Key Laboratory of Metal Materials Characterization, Central Iron & Steel Research Institute, Beijing 100081, China.
  • Wan W; Qingdao NCS Testing & Corrosion Protection Technology Co., Ltd., Qingdao 266071, China.
  • Yan Z; National Observation & Research Station on Materials Corrosion in Marine and Atmospheric Environment in Qingdao, Qingdao 266071, China.
Materials (Basel) ; 16(4)2023 Feb 15.
Article em En | MEDLINE | ID: mdl-36837234
Microscopic content segregation is among the important reasons for the anisotropy of mechanical properties in the cast-rolled sheets of the 7B05 aluminum alloy. It is of great significance to study the uniformity of aluminum alloys in terms of the microscopic composition and structure. In this study, a precise method for composition quantification based on micro-beam X-ray fluorescence spectroscopy is established by parameter optimization and a calibration coefficient. Furthermore, this method was applied for exploring and quantifying the relationship between recrystallization and deformation microstructures. The results show that the comprehensive measurement effects of all elements are the best when the X-ray tube voltage is 50 kV, the current is 150 µA, and the single-pixel scanning time is 100 ms. After verification, the sum of differences between the measured values and the standard values for all elements using the calibration coefficient is only 0.107%, which confirms the accuracy of the optimized quantitative method. Three types of segregation indexes in national standards were used to capture small differences, and finally ensure that the segregation degrees of elements are Ti > Fe > Cr > Cu > Mn > Zr > Zn > Al. The quantitative segregation results obtained by the spatial-mapping method show that the difference in the content of Al and Zn is approximately 0.2% between the recrystallization region and the deformation region, the difference in the content of Fe and Ti is 0.018% and 0.013%, the difference in the content of Cr, Cu and Zr is approximately 0.01%, and the difference in the content of Mn is not obvious, only 0.004%.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Materials (Basel) Ano de publicação: 2023 Tipo de documento: Article País de afiliação: China

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Materials (Basel) Ano de publicação: 2023 Tipo de documento: Article País de afiliação: China
...