Your browser doesn't support javascript.
loading
Fully implantable batteryless soft platforms with printed nanomaterial-based arterial stiffness sensors for wireless continuous monitoring of restenosis in real time.
Herbert, Robert; Elsisy, Moataz; Rigo, Bruno; Lim, Hyo-Ryoung; Kim, Hyeonseok; Choi, Chanyeong; Kim, Seungil; Ye, Sang-Ho; Wagner, William R; Chun, Youngjae; Yeo, Woon-Hong.
Afiliação
  • Herbert R; George W. Woodruff School of Mechanical Engineering, Georgia Institute of Technology, Atlanta, GA 30332, USA.
  • Elsisy M; IEN Center for Human-Centric Interfaces and Engineering at the Institute for Electronics and Nanotechnology, Georgia Institute of Technology, Atlanta, GA 30332, USA.
  • Rigo B; Department of Industrial Engineering, Swanson School of Engineering, University of Pittsburgh, Pittsburgh, PA 15260, USA.
  • Lim HR; IEN Center for Human-Centric Interfaces and Engineering at the Institute for Electronics and Nanotechnology, Georgia Institute of Technology, Atlanta, GA 30332, USA.
  • Kim H; School of Electrical and Computer Engineering, Georgia Institute of Technology, Atlanta, GA 30332, USA.
  • Choi C; Major of Human Biocovergence, Division of Smart Healthcare, College of Information Technology and Convergence, Pukyong National University, Busan 48513, Republic of Korea.
  • Kim S; George W. Woodruff School of Mechanical Engineering, Georgia Institute of Technology, Atlanta, GA 30332, USA.
  • Ye SH; IEN Center for Human-Centric Interfaces and Engineering at the Institute for Electronics and Nanotechnology, Georgia Institute of Technology, Atlanta, GA 30332, USA.
  • Wagner WR; George W. Woodruff School of Mechanical Engineering, Georgia Institute of Technology, Atlanta, GA 30332, USA.
  • Chun Y; IEN Center for Human-Centric Interfaces and Engineering at the Institute for Electronics and Nanotechnology, Georgia Institute of Technology, Atlanta, GA 30332, USA.
  • Yeo WH; McGowan Institute for Regenerative Medicine, University of Pittsburgh, Pittsburgh, PA 15260, USA.
Nano Today ; 462022 Oct.
Article em En | MEDLINE | ID: mdl-36855693
Atherosclerosis is a common cause of coronary artery disease and a significant factor in broader cardiovascular diseases, the leading cause of death. While implantation of a stent is a prevalent treatment of coronary artery disease, a frequent complication is restenosis, where the stented artery narrows and stiffens. Although early detection of restenosis can be achieved by continuous monitoring, no available device offers such capability without surgeries. Here, we report a fully implantable soft electronic system without batteries and circuits, which still enables continuous wireless monitoring of restenosis in real-time with a set of nanomembrane strain sensors in an electronic stent. The low-profile system requires minimal invasive implantation to deploy the sensors into a blood vessel through catheterization. The entirely printed, nanomaterial-based set of soft membrane strain sensors utilizes a sliding mechanism to offer enhanced sensitivity and detection of low strain while unobtrusively integrating with an inductive stent for passive wireless sensing. The performance of the soft sensor platform is demonstrated by wireless monitoring of restenosis in an artery model and an ex-vivo study in a coronary artery of ovine hearts. The capacitive sensor-based artery implantation system offers unique advantages in wireless, real-time monitoring of stent treatments and arterial health for cardiovascular disease.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Prognostic_studies / Screening_studies Idioma: En Revista: Nano Today Ano de publicação: 2022 Tipo de documento: Article País de afiliação: Estados Unidos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Prognostic_studies / Screening_studies Idioma: En Revista: Nano Today Ano de publicação: 2022 Tipo de documento: Article País de afiliação: Estados Unidos
...