Your browser doesn't support javascript.
loading
A Comparison of the Corneal Thickness Following Descemet's Stripping Automated Endothelial Keratoplasty and Descemet's Membrane Endothelial Keratoplasty.
Sunouchi, Chihiro; Hayashi, Takahiko; Shimizu, Toshiki; Hara, Yusuke; Kurita, Junki; Kobashigawa, Hiroko; Oyakawa, Itaru; Ida, Yasutsugu; Kobayashi, Akira; Shoji, Jun; Yamagami, Satoru.
Afiliação
  • Sunouchi C; Department of Ophthalmology, Nihon University of Medicine, Tokyo, Japan.
  • Hayashi T; Department of Ophthalmology, Nihon University of Medicine, Tokyo, Japan.
  • Shimizu T; Department of Ophthalmology, Yokohama Minami Kyosai Hospital, Kanagawa, Japan.
  • Hara Y; Department of Ophthalmology, Nihon University of Medicine, Tokyo, Japan.
  • Kurita J; Department of Ophthalmology, Nihon University of Medicine, Tokyo, Japan.
  • Kobashigawa H; Department of Ophthalmology, Nihon University of Medicine, Tokyo, Japan.
  • Oyakawa I; Yokosuka Chuo Eye Clinic, Kanagawa, Japan.
  • Ida Y; Department of Ophthalmology, Heart Life Hospital, Okinawa, Japan.
  • Kobayashi A; Department of Ophthalmology, Yokohama Minami Kyosai Hospital, Kanagawa, Japan.
  • Shoji J; Department of Ophthalmology, Graduate School of Medical Science, Kanazawa University, Ishikawa, Japan.
  • Yamagami S; Department of Ophthalmology, Nihon University of Medicine, Tokyo, Japan.
Curr Eye Res ; 48(8): 712-718, 2023 08.
Article em En | MEDLINE | ID: mdl-37052462
ABSTRACT

PURPOSE:

To compare the central corneal thickness before and after Descemet's stripping automated endothelial keratoplasty (DSAEK) and Descemet's membrane endothelial keratoplasty (DMEK), and to evaluate the recipient corneal thickness following DSAEK.

METHODS:

The corneal thickness was compared between two groups of eyes following DMEK and DSAEK, performed by a single surgeon between 2015 and 2017. We evaluated the recipient corneal thickness and central corneal thickness pre- and postoperatively at 1, 3, and 6 months using anterior segment optical coherence tomography. Recipient corneal thickness was defined as the corneal thickness without graft thickness.

RESULTS:

We included DMEK and DSAEK eyes (n = 26 each), which were similar in terms of their etiologies. Preoperatively, there was no significant difference in the central corneal thickness between the groups (DSAEK, median [interquartile range] 721 [606.5 to 847.8] µm; and DMEK 690 [618 to 722.3] µm; p = 0.30). Despite the tendency of the central corneal thickness to be significantly greater (p < .01) at 6 months following DSAEK (619.5 [607.8 to 661.3] µm) compared with that following DMEK (497.5 [475.8 to 525.3] µm), there was no significant difference at 6 months between the recipient corneal thickness following DSAEK (488.5 [443.8 to 515] µm) and central corneal thickness following DMEK (p = 0.54).

CONCLUSIONS:

DSAEK eyes display a similar tendency of stromal thinning as DMEK eyes.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Lâmina Limitante Posterior / Ceratoplastia Endotelial com Remoção da Lâmina Limitante Posterior Idioma: En Revista: Curr Eye Res Ano de publicação: 2023 Tipo de documento: Article País de afiliação: Japão

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Lâmina Limitante Posterior / Ceratoplastia Endotelial com Remoção da Lâmina Limitante Posterior Idioma: En Revista: Curr Eye Res Ano de publicação: 2023 Tipo de documento: Article País de afiliação: Japão
...