Your browser doesn't support javascript.
loading
Inferior implant of XEN63 Gel stent in a refractory open-angle glaucoma due to silicone oil tamponade: A case report.
Savastano, Alfonso; Carlà, Matteo Mario; Gambini, Gloria; Giannuzzi, Federico; Boselli, Francesco; Rizzo, Stanislao.
Afiliação
  • Savastano A; Ophthalmology Unit, "Fondazione Policlinico Universitario A. Gemelli, IRCCS", Rome, Italy.
  • Carlà MM; Ophthalmology Unit, Catholic University "Sacro Cuore", Rome, Italy.
  • Gambini G; Ophthalmology Unit, "Fondazione Policlinico Universitario A. Gemelli, IRCCS", Rome, Italy.
  • Giannuzzi F; Ophthalmology Unit, Catholic University "Sacro Cuore", Rome, Italy.
  • Boselli F; Ophthalmology Unit, "Fondazione Policlinico Universitario A. Gemelli, IRCCS", Rome, Italy.
  • Rizzo S; Ophthalmology Unit, Catholic University "Sacro Cuore", Rome, Italy.
Eur J Ophthalmol ; 34(1): NP27-NP31, 2024 Jan.
Article em En | MEDLINE | ID: mdl-37192674
ABSTRACT

BACKGROUND:

To discuss the efficacy of an inferior implant of XEN 63 gel stent in a patient with refractory glaucoma after trabeculectomy failure and vitreoretinal surgery with silicone oil tamponade. CASE DESCRIPTION We report the case of a 73-year-old man with a history of refractory open glaucoma with trabeculectomy failure. He experienced recurrent retinal detachments with silicone oil tamponade, with uncontrolled intra-ocular pressure (IOP) after silicone oil removal. Due to the presence of oil emulsion in the anterior chamber, the chosen location for XEN 63 implantation was the infero-temporal quadrant. Mild hyphema and vitreous hemorrhage were seen post-operatively, but were self-limiting. At week 1, the intraocular pressure was 8 mmHg with a well-formed bleb seen in anterior segment optical coherence tomography (AS-OCT). At 6 month follow up, the patient maintained a IOP of 12 mmHg without topical hypotensive drugs. Slit lamp examination revealed a widespread, developed bleb with no signs of inflammation.

CONCLUSION:

In this case of refractory glaucoma in a vitrectomized eye with previous oil tamponade, the inferior placement of the XEN 63 gel stent delivered an adequate intraocular pressure even at 6-months follow up, with a diffuse functional infero-nasal bleb seen with AS-OCT.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Glaucoma / Glaucoma de Ângulo Aberto / Implantes para Drenagem de Glaucoma Limite: Aged / Humans / Male Idioma: En Revista: Eur J Ophthalmol Assunto da revista: OFTALMOLOGIA Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Itália

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Glaucoma / Glaucoma de Ângulo Aberto / Implantes para Drenagem de Glaucoma Limite: Aged / Humans / Male Idioma: En Revista: Eur J Ophthalmol Assunto da revista: OFTALMOLOGIA Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Itália
...