Intrarectal Foley catheter-assisted high-intensity focused ultrasound ablation for benign uterine diseases beyond the treatment region.
Liu, Wei; Kim, Tae-Hee; Huang, Lihui; Chen, Xing; Feng, Chunping; Liu, Ling; Zhang, Li; Zhang, Wen; Zhou, Kun; Gan, Xiuni.
Afiliação
  • Liu W; Clinical Center for Tumor Therapy, The Second Affiliated Hospital, Chongqing Medical University, Chongqing, China.
  • Kim TH; Seoul HIcare Clinic, Seoul, Korea.
  • Huang L; Clinical Center for Tumor Therapy, The Second Affiliated Hospital, Chongqing Medical University, Chongqing, China.
  • Chen X; Clinical Center for Tumor Therapy, The Second Affiliated Hospital, Chongqing Medical University, Chongqing, China.
  • Feng C; Clinical Center for Tumor Therapy, The Second Affiliated Hospital, Chongqing Medical University, Chongqing, China.
  • Liu L; Clinical Center for Tumor Therapy, The Second Affiliated Hospital, Chongqing Medical University, Chongqing, China.
  • Zhang L; Clinical Center for Tumor Therapy, The Second Affiliated Hospital, Chongqing Medical University, Chongqing, China.
  • Zhang W; Clinical Center for Tumor Therapy, The Second Affiliated Hospital, Chongqing Medical University, Chongqing, China.
  • Zhou K; Clinical Center for Tumor Therapy, The Second Affiliated Hospital, Chongqing Medical University, Chongqing, China.
  • Gan X; Nursing Department, The Second Affiliated Hospital, Chongqing Medical University, Chongqing, China.
Int J Hyperthermia ; 40(1): 2219435, 2023.
Article em En | MEDLINE | ID: mdl-37344381
ABSTRACT

OBJECTIVE:

To evaluate the feasibility of using an intrarectal Foley catheter during ultrasound-guided high-intensity focused ultrasound (US-HIFU) in patients with benign uterine diseases of the posterior wall beyond the HIFU therapeutic range.

METHODS:

Patients were treated with US-HIFU and lesion changes were monitored using contrast-enhanced MRI from June 2020 to September 2021. A Foley catheter was inserted into the rectum to facilitate a successful US-HIFU ablation. Complications and lesion responses were recorded during the treatment and follow-up.

RESULTS:

Thirteen patients with 14 lesions beyond the device's treatable area were enrolled. The average placement time and insertion depth of the intrarectal Foley catheter was 7.6 ± 2.7 min and 23.2 ± 7.6 cm, respectively. A median of 50 mL degassed water was injected into the Foley catheter balloon. All 14 lesions were successfully pushed into a treatable area and subjected to HIFU. The average treatment time, irradiation time, and total therapeutic energy of HIFU were 44.2 ± 17.3 min, 394.4 ± 295.7 s, and 73.3 ± 46.6 kJ, respectively. The mean non-perfusion volume (NPV) in all treated lesions was 23.2 ± 19.2 cm3, and the mean NPV ratio was 57.8 ± 16.9%. Major complications were not observed.

CONCLUSION:

Intrarectal Foley catheter-assisted US-HIFU is effective and safe. Its clinical application could benefit patients with benign uterine diseases outside the HIFU therapeutic range.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Doenças Uterinas / Neoplasias Uterinas / Ablação por Ultrassom Focalizado de Alta Intensidade / Leiomioma Limite: Female / Humans Idioma: En Revista: Int J Hyperthermia Assunto da revista: NEOPLASIAS / TERAPEUTICA Ano de publicação: 2023 Tipo de documento: Article País de afiliação: China

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Doenças Uterinas / Neoplasias Uterinas / Ablação por Ultrassom Focalizado de Alta Intensidade / Leiomioma Limite: Female / Humans Idioma: En Revista: Int J Hyperthermia Assunto da revista: NEOPLASIAS / TERAPEUTICA Ano de publicação: 2023 Tipo de documento: Article País de afiliação: China
...