Your browser doesn't support javascript.
loading
Feasibility and clinical usefulness of deep learning-accelerated MRI for acute painful fracture patients wearing a splint: A prospective comparative study.
Roh, Seunghyeon; Park, Jae In; Kim, Gun Young; Yoo, Hye Jin; Nickel, Dominik; Koerzdoerfer, Gregor; Sung, JaeKon; Oh, Jiseon; Chae, Hee Dong; Hong, Sung Hwan; Choi, Ja-Young.
Afiliação
  • Roh S; Department of Radiology, Seoul National University Hospital, Seoul, Republic of Korea.
  • Park JI; Department of Radiology, Seoul National University College of Medicine, Seoul, Republic of Korea.
  • Kim GY; Department of Radiology, Seoul National University Hospital, Seoul, Republic of Korea.
  • Yoo HJ; Department of Radiology, Seoul National University Hospital, Seoul, Republic of Korea.
  • Nickel D; Department of Radiology, Seoul National University Hospital, Seoul, Republic of Korea.
  • Koerzdoerfer G; Department of Radiology, Seoul National University College of Medicine, Seoul, Republic of Korea.
  • Sung J; Siemens Healthcare GmbH, Erlangen, Germany.
  • Oh J; Siemens Healthcare GmbH, Erlangen, Germany.
  • Chae HD; Siemens Healthineers Ltd, Seoul, Republic of Korea.
  • Hong SH; Department of Radiology, Seoul National University Hospital, Seoul, Republic of Korea.
  • Choi JY; Department of Radiology, Seoul National University College of Medicine, Seoul, Republic of Korea.
PLoS One ; 18(6): e0287903, 2023.
Article em En | MEDLINE | ID: mdl-37379272
OBJECTIVE: To evaluate the feasibility and clinical usefulness of deep learning (DL)-accelerated turbo spin echo (TSEDL) sequences relative to standard TSE sequences (TSES) for acute radius fracture patients wearing a splint. METHODS: This prospective consecutive study investigated 50 patients' preoperative wrist MRI scans acquired between July 2021 and January 2022. Examinations were performed at 3 Tesla MRI with body array coils due to the wrist splint. Besides TSES obtained according to the routine protocol, TSEDL sequences for axial T2-, coronal T1-, and coronal PD-weighted TSE sequences were scanned for comparison. For quantitative assessment, the relative signal-to-noise ratio (rSNR), the relative contrast-to-noise ratio (rCNR), and the relative contrast ratio (rCR) were measured. For qualitative assessment, all images were assessed by two independent musculoskeletal radiologists in terms of perceived SNR, image contrast, image sharpness, artifacts disturbing evaluation, overall image quality and diagnostic confidence for injuries using a four- or five-point Likert scale. RESULTS: The scan time was shortened approximately by a factor of two for TSEDL compared to TSES. TSEDL images showed significantly better rSNR, rCNR, and rCR values for all sequences, and scored significantly better in terms of both image quality and diagnostic confidence for both readers than TSES images (all p < .05). Interrater reliabilities were in almost perfect agreement. CONCLUSION: The DL-accelerated technique proved to be very helpful not only to reduce scan time but also to improve image quality for acute painful fracture patients wearing a splint despite using body array coils instead of a wrist-specific coil. Based on our study, the DL-accelerated technique can be very useful for MRI of any part of the extremities in trauma settings just with body array coils.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Fraturas do Rádio / Aprendizado Profundo Tipo de estudo: Guideline / Observational_studies / Qualitative_research Limite: Humans Idioma: En Revista: PLoS One Assunto da revista: CIENCIA / MEDICINA Ano de publicação: 2023 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Fraturas do Rádio / Aprendizado Profundo Tipo de estudo: Guideline / Observational_studies / Qualitative_research Limite: Humans Idioma: En Revista: PLoS One Assunto da revista: CIENCIA / MEDICINA Ano de publicação: 2023 Tipo de documento: Article
...