Your browser doesn't support javascript.
loading
Evaluation of a Sample-to-Result POCKIT Central SARS-CoV-2 PCR System.
Zhu, Jin-Hui; Tai, Chia-Hsing; Ping, Chia-Fong; Chou, Pin-Hsing; Tsai, Yun-Long; Chung, Simon; Bradner, Laura; Pentella, Michael; Gauger, Phillip; Zhang, Jianqiang.
Afiliação
  • Zhu JH; Department of Veterinary Diagnostic and Production Animal Medicine, College of Veterinary Medicine, Iowa State University, Ames, IA 50011, USA.
  • Tai CH; GeneReach Biotechnology Corporation, Taichung 407, Taiwan.
  • Ping CF; GeneReach Biotechnology Corporation, Taichung 407, Taiwan.
  • Chou PH; GeneReach Biotechnology Corporation, Taichung 407, Taiwan.
  • Tsai YL; GeneReach Biotechnology Corporation, Taichung 407, Taiwan.
  • Chung S; GeneReach Biotechnology Corporation, Taichung 407, Taiwan.
  • Bradner L; Department of Veterinary Diagnostic and Production Animal Medicine, College of Veterinary Medicine, Iowa State University, Ames, IA 50011, USA.
  • Pentella M; State Hygienic Laboratory, University of Iowa, Coralville, IA 52241, USA.
  • Gauger P; Department of Veterinary Diagnostic and Production Animal Medicine, College of Veterinary Medicine, Iowa State University, Ames, IA 50011, USA.
  • Zhang J; Department of Veterinary Diagnostic and Production Animal Medicine, College of Veterinary Medicine, Iowa State University, Ames, IA 50011, USA.
Diagnostics (Basel) ; 13(13)2023 Jun 29.
Article em En | MEDLINE | ID: mdl-37443612
ABSTRACT
The emergence of COVID-19 has caused unprecedented impacts on global public health and many other aspects. Meanwhile, many types of methods have been developed to detect the causative agent, SARS-CoV-2; this has greatly advanced the technologies in the diagnostic field. Here, we describe the development and validation of a sample-in-result-out POCKIT Central SARS-CoV-2 PCR system for detecting SARS-CoV-2 in comparison with a commercial reference real-time RT-PCR assay (TaqPath COVID-19 Combo Kit). Both assays were specific and did not cross-react with non-SARS-CoV-2 agents. Both assays were able to detect various SARS-CoV-2 strains including some variants. Based on testing serial dilutions of SARS-CoV-2 USA-WA1/2020 isolate, the limit of detection was 0.8 TCID50/mL (1.87 × 103 genomic copies/mL) for POCKIT Central SARS-CoV-2 PCR and 0.16 TCID50/mL (3.75 × 102 genomic copies/mL) for the reference PCR. Subsequently, 183 clinical samples were tested by both assays and the diagnostic sensitivity, specificity, and agreement of the POCKIT Central SARS-CoV-2 PCR were 91.7%, 100%, and 94.0%, respectively, when compared to the reference PCR. The compact sample-to-result POCKIT Central SARS-CoV-2 PCR system is a simplified and efficient point-of-care tool for SARS-CoV-2 detection. In addition, this platform can be readily adapted to detect other human and animal viruses.