Your browser doesn't support javascript.
loading
Inverted Pedicled Internal Limiting Membrane Flap Attached to an Optic Disc with Autologous Blood Clot for Large Macular Holes.
Zhang, Lishuai; Xi, Huiyu; Chen, Jiayu; Sheng, Aiqin; Fan, Wei; Li, Suyan; Liu, Haiyang.
Afiliação
  • Zhang L; The Affiliated Xuzhou Municipal Hospital of Xuzhou Medical University, Xuzhou, China.
  • Xi H; Department of Ophthalmology, Xuzhou First People's Hospital, Xuzhou, China.
  • Chen J; Eye Disease Prevention and Treatment Institute of Xuzhou, Xuzhou, China.
  • Sheng A; The Affiliated Xuzhou Municipal Hospital of Xuzhou Medical University, Xuzhou, China.
  • Fan W; Department of Ophthalmology, Xuzhou First People's Hospital, Xuzhou, China.
  • Li S; Eye Disease Prevention and Treatment Institute of Xuzhou, Xuzhou, China.
  • Liu H; The Affiliated Xuzhou Municipal Hospital of Xuzhou Medical University, Xuzhou, China.
J Ophthalmol ; 2023: 7640476, 2023.
Article em En | MEDLINE | ID: mdl-37483314
ABSTRACT

Purpose:

An inverted ILM flap might be accidentally separated from the retina or sucked away during surgery for large macular holes (MHs). This article is to determine the efficacy of a new inverted pedicled internal limiting membrane (ILM) flap attached to an optic disc with an autologous blood clot (ABC) technique for the treatment of large MHs.

Methods:

An inverted pedicled ILM flap connected to the optic disc with ABC was used to treat 12 consecutive patients with significant macular holes (>600 m). The ILM was first peeled off around MH as a semidiameter of about 1.5 diameters of the optic disc. The superior residual ILM was used to produce a pedicled ILM flap that was connected to the optic disc and was later inverted to cover the MH. The macular hole was covered with a repositioned flap larger than 2 MH diameters in an inverted way. ABC was used to fasten the flap, followed by fluid-air exchange with air or C3F8 as tamponade. Spectral domain-optical coherence tomography (SD-OCT) and best-corrected visual acuity (BCVA) were performed at each postoperative follow-up.

Results:

The mean aperture and base macular hole diameters were 737.9 ± 109.6 µm (range, 607-982 µm) and 1244.3 ± 227.4 µm (range, 975-1658 µm). All macular holes (100%) were closed after a single surgery without intraoperative or postoperative complications related to the ILM transposition technique. At the last postoperative visit, we found one eye with a U-shaped closure, three eyes with W-shaped closures, and eight eyes with V-shaped closures. No postoperative flap closures were noted in all cases. The preoperative mean BCVA was 1.5 ± 0.3 (range, 1.1-2.0). After a mean follow-up of 5.3 ± 4.8 (range, 3-16) months, the postoperative mean BCVA was 0.8 ± 0.2 (range, 0.6-1.1), and the difference was statistically significant (p < 0.05).

Conclusion:

This novel technique is safe and suitable for large MHs and can be an alternative option for accidental ILM flap loss during other inverted ILM flap operations.

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: J Ophthalmol Ano de publicação: 2023 Tipo de documento: Article País de afiliação: China

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: J Ophthalmol Ano de publicação: 2023 Tipo de documento: Article País de afiliação: China
...