Your browser doesn't support javascript.
loading
Analyzing force measurements of multi-cellular clusters comprising indeterminate geometries.
Brill-Karniely, Yifat; Tischenko, Katerina; Benny, Ofra.
Afiliação
  • Brill-Karniely Y; Institute for Drug Research, The School of Pharmacy, Faculty of Medicine, The Hebrew University of Jerusalem, 9112001, Jerusalem, Israel. yifat.brill@mail.huji.ac.il.
  • Tischenko K; Institute of Animal Science, ARO, The Volcani Center, 50250, Bet-Dagan, Israel. yifat.brill@mail.huji.ac.il.
  • Benny O; Institute for Drug Research, The School of Pharmacy, Faculty of Medicine, The Hebrew University of Jerusalem, 9112001, Jerusalem, Israel.
Biomech Model Mechanobiol ; 23(1): 145-155, 2024 Feb.
Article em En | MEDLINE | ID: mdl-37770729
ABSTRACT
Multi-cellular biomimetic models often comprise heterogenic geometries. Therefore, quantification of their mechanical properties-which is crucial for various biomedical applications-is a challenge. Due to its simplicity, linear fitting is traditionally used in analyzing force-displacement data of parallel compression measurements of multi-cellular clusters, such as tumor spheroids. However, the linear assumption would be artificial when the contact geometry is not planar. We propose here the integrated elasticity (IE) regression, which is based on extrapolation of established elastic theories for well-defined geometries, and is free, extremely simple to apply, and optimal for analyzing coarsely concave multi-cellular clusters. We studied here the quality of the data analysis in force measurements of tumor spheroids comprising different types of melanoma cells, using either the IE or the traditional linear regressions. The IE regression maintained excellent precision also when the contact geometry deviated from planarity (as shown by our image analysis). While the quality of the linear fittings was relatively satisfying, these predicted smaller elastic moduli as compared to the IE regression. This was in accordance with previous studies, in which the elastic moduli predicted by linear fits were smaller compared to those obtained by well-established methods. This suggests that linear regressions underestimate the elastic constants of bio-samples even in cases where the fitting precision seems satisfying, and highlights the need in alternative methods as the IE scheme. For comparison between different types of spheroids we further recommend to increase the soundness by regarding relative moduli, using universal reference samples.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Fenômenos Mecânicos / Neoplasias Tipo de estudo: Prognostic_studies Limite: Humans Idioma: En Revista: Biomech Model Mechanobiol Assunto da revista: ENGENHARIA BIOMEDICA Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Israel

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Fenômenos Mecânicos / Neoplasias Tipo de estudo: Prognostic_studies Limite: Humans Idioma: En Revista: Biomech Model Mechanobiol Assunto da revista: ENGENHARIA BIOMEDICA Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Israel
...